DIAGNOSTICS AND TROUBLESHOOTING AND FAULTS
The device runs two separate testing procedures:
1. Start-up testing – when the device is switched on it checks the status of the module
and the internal connections before powering the motor control relay
2. Run-time testing – during operation, the device monitors the operating conditions
when the relay is powered, as well as the battery charge
In the event that the controller detects alarm conditions, an error code is generated
which is displayed using the LED on the front of the device, and winch operation
is prevented.
Table of errors
LED on fixed: no error, device on and not activated
LED flashing slowly: no error, device running
No. flashes
BATTERY UNDER
1
VOLTAGE/
DISCHARGED
CURRENT SENSOR
2
ERROR
3
COIL ERROR
INTERNAL SYSTEM
4
ERROR
BUTTON PRESSED AT
5
START-UP
TWO BUTTONS
6
PRESSED
INTERNAL SYSTEM
7
ERROR
BATTERY
8
OVERVOLTAGE
ERROR
Recharge the battery, checking that the
device is compatible with the on-board
system.
Contact Harken
replace the device.
Contact Harken
replace the device.
Contact Harken
replace the device.
Release the button / check the wiring
Release the buttons and press one
only.
Contact Harken
replace the device.
Check that the device is compatible
with the on-board system.
english
SOLUTION
support /
®
support /
®
support /
®
support /
®
13