Connect the fixture wires to the wires in the junction box.
Twist the wires together and secure with wire connectors.

Recommended Grounding Method

Use a green ground "pigtail" (not provided) and twist
one end together with the bare fixture wire and the box
ground wire. Secure with a wire connector. Secure the
other end of the "pigtail" with the GND screw on the
mounting plate.
If you have metal junction box, you may not need the green
"pigtail". If you are unsure about the grounding method,
consult your local building code.
White to white
Black to black
4

MOUNTING THE LIGHT FIXTURE

1. Make sure wire connectors and wires are inside the
junction box.
2. Slide the fixture assembly onto the mounting screws.
Tighten decorative nuts removed in step 1 of Light
Fixture Installation section securely against fixture base.
Decorative Nut
3. Install one medium base light bulb (100 Watt maximum,
tungsten incandescent).
4. Caulk around fixture base with silicone weather sealant.
Caulking Around Fixture Base
Mounting Screw
Junction
Box