Motion Sensor Light
Control
As an ENERGY STAR
Zenith has determined that this product
meets the ENERGY STAR
energy efficiency. This product is ENERGY
®
STAR
compliant when used with 120 Watt bulbs.
Model SL-5411
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
This package includes:
Lamp
Holders
Cover
Plate
Light Control
Mounting Bolt
Mounting Strap
6 Screws
(3 sizes included)
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
© 2002 DESA International
®
Partner, Heath
®
guidelines for
Rubber Plug
Plastic Hanger
Sensor
2 Wire
Connectors
Gasket
OPERATION
Mode:
On-Time:
Test
5 Sec
Auto
1, 5, 10 min.
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
®
/
the circuitry to calibrate.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5 or
10 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the ON-
TIME switch in the 1, 5, or 10 position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
Works:
Day
x
1
/
minutes for
2
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
1 Second OFF
then...
... back on.
Move ON-TIME Switch to
1, 5 or 10 minutes
Flip light switch off
for one second then
back on*
595-4884-17
Night
x
x
x
Tabla de contenido
loading

Resumen de contenidos para Heath Zenith SL-5411

  • Página 1 STAR compliant when used with 120 Watt bulbs. ON-TIME Put the ON-TIME switch on the bottom of the sensor in the TEST position. Model SL-5411 10 5 1 TEST Features AUTO • Turns on lighting when motion is detected. ON-TIME •...
  • Página 2: Wall Mount

    ❒ Route the Light Control’s wires through the large INSTALLATION gasket holes. ❒ Twist the junction box wires and fixture wires together For easy installation, select an existing light with a wall switch for replacement. as shown. Secure with wire connectors. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9...
  • Página 3 ❒ Loosen the clamp screw in TEST AND ADJUSTMENT Clamp the sensor ball joint and gen- Screw ❒ Turn on the circuit breaker and light switch. tly rotate the sensor. ❒ Turn the RANGE control to the mid position and the ❒...
  • Página 4: Troubleshooting Guide

    TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Lights will not come 1. Light switch is turned off. Lights stay on 1. A flood lamp is positioned too close to 2. Flood light loose continuously. the sensor or pointed at nearby ob- burned out.
  • Página 5: Control De Luz Del Detector De Movimiento

    Este producto está en conformidad con ENERGY ® STAR cuando se usa con focos de 120 vatios. Para PRUEBA: ON-TIME Modelo SL-5411 Ponga el interruptor de tiempo (ON- TIME), al fondo del detector, en la Características posición de prueba (TEST). 10 5 1 TEST •...
  • Página 6: Instalacion

    ❒ Conecte los cables de la caja de empalme con los INSTALACION cables del aparato de luz, como se muestra. Tuérazalos Para una fácil instalación escoja una luz con un juntos y asegúrelos con un conector de cables. interruptor de pared. lámina de 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 Negro a...
  • Página 7: Prueba Y Ajuste

    ❒ Afloje el tornillo sujetador en PRUEBA Y AJUSTE Tornillo la unión esférica y gire Sujetador ❒ Prenda el cortacircuitos y el interruptor de luz. despacio el detector. ❒ Gire el control RANGE a la posición media y el ❒ Camine por el área a Unión control ON-TIME a la posición TEST.
  • Página 8: Guia De Investigacion De Averias

    GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA 1. El interruptor de luz está La luz se 1. Un faro está colocado demasiado cerca enciende. apagado. queda al detector o apunta a objetos cercanos 2. El faro está flojo o fundido. prendida que hace que el calor active el detector.
  • Página 9 ® est conforme à ENERGY STAR lorsqu’il est utilisé avec des minute pour que l’étalonnage du circuit soit ampoules de 120 watts. complété. Modèle SL-5411 ESSAI ON-TIME Amener en position d’essai (TEST) Caractéristiques l’interrupteur de temps en circuit (ON- • Allume l’éclairage lorsqu’un mouvement est détecté.
  • Página 10: Montage Mural

    ❒ Faire passer les fils de la commande d'éclairage INSTALLATION par le trou de la garniture. ❒ Torsader les fils de la boîte de jonction avec ceux Pour faciliter l’installation, choisir un appareil d’éclairage devant être remplacé et qui est déjà de la commande d’éclairage.
  • Página 11: Essais Et Réglages

    ❒ Desserrer la vis de blocage ESSAIS ET RÉGLAGES Vis de de la rotule et faire pivoter le blocage ❒ Mettre en circuit le disjoncteur et l’interrupteur détecteur pour pointer. d’éclairage. ❒ Marcher dans la zone de Rotule ❒ Placez la commande RANGE à sa position couverture et noter à...
  • Página 12: Guide De Dépannage

    GUIDE DE DÉPANNAGE SYMPTÔME CAUSE POSSIBLE SYMPTÔME CAUSE POSSIBLE L’éclairage ne 1. L’interrupteur d’éclairage est hors L’éclairage reste 1. Un projecteur est situé trop près du s’allume pas. tension. allumé détecteur ou pointé vers des objets 2. Le projecteur est dévissé ou brûlé. continuellement.