Troubleshooting; Maintenance - Sagola COMPACT 220 Manual De Instrucciones

Ocultar thumbs Ver también para COMPACT 220:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

The air pressure in the air network:
MUST BE MAXIMUM 7 BAR
THE EQUIPMENT COMPACT 220
IS ADJUSTED ON 4 BAR
Occasionally poor functioning of the machine may
occur. In such cases refrain from using the machine
and arrange the necessary maintenance before
incurring in risk of accidents or damages.
Malfunction
The automatic wash
cycle does not start
The suction does not
start
The safety devices should always be in an optimal
state and should not be removed.
- Disconnect the compressed air supply in case of
repairs or maintenance.
- Periodically check the integrity and functionality of
safety devices.
- Periodically clean the discharge area, cleaning area,
and control valves.

10. TROUBLESHOOTING

Cause
The pneumatic supply of the machine is
disconnected
The shut-off valve on the compressed air
supply line is closed
The pneumatic pump has stalled
The general ON/OFF switch machine is off
The lid of the automatic wash tank is open
The valve on the tank lid is blocked
Timer broken
The general ON/OFF switch machine is off
The pneumatic supply of the machine is
disconnected
The shut-off valve on the compressed air
supply line is closed

11. MAINTENANCE

- 18 -
WARNING:
The pump should never work empty.
WARNING:
The total amount of solvent introduced to clean
recirculation and cleaning solvent should not exceed
the total capacity of the bottle containing the solvent
for recirculation to prevent overflow.
Call the manufacturer for any information or if you
have any doubts before working.
The following describes the possible malfunctions,
causes and remedies:
Remedy
Connect the machine up to the pneumatic
supply
Open the shut-off valve on the compressed
air supply line.
Press the reset button on the pump using
the special blunt instrument of Ø 4/5 mm
Turn the general ON/OFF switch machine to
the ON position
Close the lid of the tank
Replace the valve on the tank lid
Replace the timer
Turn the general ON/OFF switch to the ON
position
Connect the machine up to the pneumatic
supply
Open the shut-off valve on the compressed
air supply line
- Clean and replace the pump suction filter.
- The safety labels must always be clearly visible,
clean and immediately replaced in case of damage.
- It is absolutely forbidden to perform operations with
the equipment when all labels are not clearly visible.
THE EQUIPMENT ALWAYS MUST BE
CONNECTED TO GROUND