TROUBLESHOOTING

Trouble
The motors do not work, error code
on display
The machine does not move
The recovery water vacuuming is
insufficient.
The solution flow to the brushes is
insufficient.
The squeegee leaves marks on the
floor.
NOTE
If the machine is installed with the optional on-board charger, and when the on-board
charger is defective, the machine can not be operated. In case of battery charger malfunction, contact an au-
thorized Service Center.
Probable causes
The battery connector is disconnected.
The batteries are completely discharged.
Error code see the table
The machine has been turned on by using the ignition key
and by keeping one of the switches pressed.
The recovery water tank is full.
The hose is disconnected from the squeegee.
The vacuum grid is clogged or the float is
stuck closed.
The squeegee is dirty or the squeegee blades
are worn or damaged.
The tank cover is not properly closed, or the gasket is dam-
aged, or the standpipe tube is clogged.
The vacuum hose is clogged.
The solution/clean water filter is dirty.
There are debris under the squeegee blades.
The squeegee blades are worn, chipped or torn.
The squeegee has not been adjusted with the knob.
Connect the battery connector.
Charge the batteries.
Restart the machine
Turn the ignition key to "0", then try to start the
machine again without pressing the switches.
Empty the tank.
Connect.
Clean the grid or check the float.
Clean and check the squeegee.
Close the cover correctly, or replace the gasket or
clean the Bend tube.
Clean.
Clean the filter.
Remove the debris.
Replace the blades.
Adjust.