SLIM FIT
VEHICLES WITH ORIGINAL POWER SUPPLY CABLING - Electrical layout
Take care not to invert polarities when connecting the unit to the power supply. If this were to happen,
the plate would not come on and the unit would not work.
Centrifugal
blower
2,6 Amp.
Az
Blue
N
Black
R
Red
V
Green
B
White
A
Yellow
Na Orange
M
Brown
Compressor
electronic
module
2 Compressor
IMPORTANT NOTE!
Electronic
Comsuption 30 mAmp.
module
25
Air conditioning for vehicles
Return
air sensor
NTC 15KΩ a 25º
Original
wiring
2,9 Amp.
PWM.
Condenser
fan
Compressor
electronic
module
1 Compressor