dirna Bergstrom bycool SLIM FIT Diagnosis De Averías página 19

Ocultar thumbs Ver también para bycool SLIM FIT:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
SLIM FIT
• Repair the possible obstruction of the blower or the electro; if the error persists,
replace the blower or electro (remove the outside cover of the unit in order to access
the blower or electro; for the blower, also remove the evaporator cover).
• Replace the 5A fuse. To access the electro or blower fuses, it is necessary to take
down the control panel access cover mounted on the front.
!
(If the error persists, contact the Authorised Technical Service).
• Reprogramme the remote control.
• Replace the remote control's battery and reprogramme.
• Replace electronic control. To access the electronic control, it is necessary to take
down the control panel access cover mounted on the front.
• Replace the remote control.
!
(If the error persists, contact the Authorised Technical Service).
• Correctly connect the control module terminals. (see attached wiring diagram).
• Replace the module(s).
• Replace the compressor(s).
• Check the pressure (the compressors disconnect after 6 bars); if necessary, recover
gas and load 250 g again per circuit. To access the compressors, modules or load
points it is necessary to take down the unit's outside cover.
!
(If the error persists, contact the Authorised Technical Service).
• Take down the front and correctly connect the belt in the keypad and in the
electronic control.
Solution
19
Air conditioning for vehicles
EN
Tabla de contenido
loading

Tabla de contenido