Application
Operation is possible in conjunction with:
- Pressurized storage heaters
Operation with low-pressure storage heaters (displacement
water heaters) is not possible.
Specifications
• Max. flow
- Spout
- Handspray
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure reducing valves
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Water connection
Notes
- Installation of backflow protection must comply with local
codes and regulations.
- An access panel must be provided for access to diverter and
hose connections.
- Major pressure differences between hot and cold water
supply should be avoided.
Installation
Layout dimensions to establish centers and proper clearences,
see dimensional drawings on fold-out page I.
The dimensional drawing and the drilling template for fitting
plate (A) (not included in the scope of deliver) show a form of
installation suggested by GROHE, for which no further
components are required, see fold-out page I.
For deviation to the suggested installation, observe minimum
clearance required for escutcheon sizes.
Prepare fitting plate (A).
Install thermostat unit, see Figs. [1], [2] and [3].
1. Fasten mounting plate (B) to fitting plate (A) centrally, from
below using screws (C), see Fig. [1].
2. Attach pre-mounted thermostat unit (D) to the fitting plate
from above using bolts (E), see Fig. [2].
3. Secure 2 diagonally-opposed screws (E) from below using
cap nuts (F).
By loosening the screws (E), the thermostat unit can be
moved to the right and to the left, in order to enable opening
and closing of the isolating valves following installation or for
maintenance purposes.
4. Connect hoses (G) with G1/2 to the thermostat unit.
5. Attach sleeve (H), see Fig. [3].
6. Grease seal (J1) of escutcheon mounting base (J2) with the
special grease supplied.
7. Attach the escutcheon mounting base (J2) to the fitting and
fasten with mounting set (J3).
8. Attach escutcheon (J).
9. Install thermostat handle (K), snap insert (L) and screw (M).
The thermostat is adjusted at the factory. If, due to
installation conditions, re-adjustment is necessary, please
see Adjustment.
1
English
Install side valve, see Figs. [3] and [4].
1. Install mounting and sealing set (N1) on the side valve
2. Fasten the side valve from above using mounting and
3. Attach escutcheon (O).
4. Attach spindle & sleeve (P).
approx. 29 L/min or 7.7 gpm
5. Connect hose (G) to the side valve with G3/4 and to the
max. 9.5 L/min or 2.5 gpm
7.25 psi
Install diverter, see Fig. [4] and fold-out page II, Fig. [5].
14.5 - 72.5 psi
1. Install mounting and sealing set (T1) on the diverter shank,
145 psi
2. Fasten the diverter housing from above using mounting
232 psi
176 °F
cold on right side
3. Attach spindle (U), see Fig. [5].
hot on left side
4. Attach escutcheon (V).
5. Install escutcheon hold down (W).
6. Install diverter knob (X).
7. Attach hose (Y) between the outlet of the volume
8. Attach hose (Y3) to the bottom port (Y4) of the diverter.
9. Attach hose (Y5) to the bath outlet port (Y6) of the diverter.
10. Make sure that the alternative inlet port (Y7) of the diverter
Install handspray, see Fig. [6].
1. Attach hose guide (Z) to fitting plate (A) using mounting
2. Install spray hose (B1) with hose (Y1).
3. Insert spray hose (B1) through hose guide (Z).
4. Attach tapered nut (D1) to spray hose (B1).
5. Insert seal (E1) in the handshower adaptor (D1). Attach
When using the handspray (F1), it must be ensured that spray
water does not penetrate the hose guide (Z).
Install spout, see Fig. [7].
1. Install shank with sealing set (G1).
2. Attach hose (Y2) between spout and diverter.
3. Attach spout (J1) to the shank and insert set screw (K1)
Flush pipes thoroughly.
Attach hoses (G) to the existing connections, see Fig. [8].
Cold water connection on right, hot water connection on
left.
Observe marking on the housing.
Check all connections for leaks
shank.
sealing set (N2).
The distance from the side valve upper edge to fitting
plate (A) must be 5/16" - 7/16", see Fig. [4].
thermostat unit with G1/2.
see Fig. [5].
and sealing set (T2).
The distance from the diverter housing upper edge to fitting
plate (A) must be 5/16" - 7/16" , see Fig. [4].
The distance from spindle (U) upper edge to fitting
plate (A) must be 2" . Fasten adjusted spindle (U) using set
screw (U1).
control (Y1) and the diverter inlet port (Y2).
is capped with the brass cap (Y8) supplied.
and sealing set (Z1).
Avoid crossing the hoses.
handspray (F1) to the handshower adaptor.
using a 4mm allen wrench.