If you install your washer in an alcove or closet, the front of the closet
must have two unobstructed air openings for a combined minimum total
area of 72 sq.in. (465 sq.cm) with a minimum clearance of 3 in. (7.6 mm)
at the top and bottom. A slatted door with equivalent space clearance is
acceptable.
48 square inches
(310 cm )
2
24 square inches
(155 cm )
2
Installing in an alcove or closet
Minimum clearances between your washer and adjacent walls or other
surfaces are:
Either side: 1 in. (2.5 cm)
Rear: 6 in. (15.2 cm)
Closet Front: 2 in. (5.1 cm)
Top: 24 in. (61 cm)
Gap between the end of water valve and the wall:
- Case 1: If you connect the supply hose after you install your washer:
Over 3.9 in. (10 cm)
- Case 2: If you connect the supply hose before you install your
washer: Over 2.8 in. (7 cm)
If you install your washer and dryer side-by-side in a closet, the closet front
must have an unobstructed air opening of at least 72 square inches
(465 square cm).
3 in.
(7.6 cm )
3 in.
(7.6 cm )