Application
Operation is possible in conjunction with:
• Pressurized storage heaters
Operation is not possible with:
• low-pressure storage heaters
(displacement water heaters)
Specifications:
• Flow pressure
Greater than 72.5 psi, fit pressure reducing valve
• Operating pressure
• Test pressure
• Max. flow
• Temperature
- Hot water inlet:
- Recommended:
- Handle rotation stop available (order No. 46 308)
• Water connection
• Deck thickness max.
• Non reversible cartridge
Notes:
* Please follow all applicable local codes when setting the
temperature on the hot water heater, as local municipalities
may have codes limiting the maximum hot water heater
setting to 122 °F.
- Major pressure differences between hot and cold water
supply should be avoided.
- To be installed according to local codes and regulations.
- This faucet is not intended for the use with portable
appliances.
Installation
Flush pipes thoroughly!
Prepare sink faucet
Refer to the dimensional drawing on fold-out page I.
Mount sink faucet
1. Fit swivel spout. Swivel range can be adjusted by means of
stop (A), see fold-out page III, fig. [1].
2. Fit O-Ring (B) and insert faucet into sink, see fig. [2].
3. Fit brace (C), if necessary, with seal (D), washer (E) and
connect nut (F).
Note:
If brace (C) is omitted, deck thickness can be increased
by 9/16" to a total of 2 3/8".
Mount handspray
1. Insert spray holder (G) through the hole, aligning the
seal (G1) with the groove on the flange, see fig. [2].
2. Tighten spray holder (G) with mounting set (H).
3. Loosely screw handspray (I) with seal (I1) onto spray
hose (J).
4. Insert spray hose (J) complete with handspray (I) through
the spray holder (G) from above.
5. Connect spray hose (J) to swivel connection (K) of the spout
body.
6. Tighten spray hose (J) with handspray (I) facing to front.
1
min. 7.25 psi
recommended 14.5 - 72.5 psi
max. 145 psi
232 psi
6.6 L/min or 1.75 gpm/60 psi
(maximum) 176 °F
122 °F* - 140 °F
cold - RH
hot - LH
2 3/8"
English
Connect sink faucet, see figs. [2] and [3].
Open hot and cold-water supply and check connections
for leakage!
Check fitting for correct operation, see fig. [4].
Flow rate limiter
This mixer is fitted with a flow rate limiter, permitting an
infinitely individual variable reduction in the flow rate. The
highest possible flow rate is set by the factory before despatch.
The use of flow rate limiters in combination with hydraulic
instantaneous water heaters is not recommended.
For commissioning see "replacing the cartridge"
point 1 to 3, fig. [5] and [6].
Maintenance
Inspect and clean all parts, replace as necessary and grease
with special grease.
Shut off hot and cold water supply!
I. Replacing the cartridge, see fig. [5].
1. Lever out plug (L).
2. Remove set screw (M) using a 3mm socket spanner and
pull off lever (N).
3. Unscrew cap (O).
4. Remove screws (P) and detach complete cartridge (R).
5. Replace complete cartridge (R).
Assemble in reverse order.
Observe the correct installation position!
Make sure that the cartridge seals engage in the grooves on
the housing. Fit screws (P) and tighten evenly and
alternately.
II. Check valve, see fig. [5].
1. Proceed as for replacing the cartridge, points 1 to 4.
2. Pull off and replace check valve (S).
III. Diverter, see fig. [7].
1. Proceed as for replacing the cartridge, points 1 to 4.
2. Loosen screw in the housing as shown in fig. [7].
3. Pull off swivel spout (T).
4. Pull out the diverter (U).
5. If necessary change seal (V).
IV.Unscrew and clean flow control (13 928/48 251),
see fold-out page II.
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.