Maintenance & Cleaning - Delabie TEMPOFLUX 3 Manual De Instrucciones

Ocultar thumbs Ver también para TEMPOFLUX 3:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
REMEMBER
• Our mixers must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer (see calculation
table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce the frequency
of maintenance (recommended pressure from 1 to 5 bar maximum).
• Install stopcocks close to the mixer to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should be checked
at least once a year, and more frequently if necessary.
MAINTENANCE & CLEANING
• Cleaning chrome, aluminium and stainless steel: do not use abrasive, chlorine or any other acid-based
cleaning products. Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the valve several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing them indoors.
MAINTENANCE
• Water discharge from the vacuum breaker: Check flush tube is not fully inserted up to the WC pan and check
flush tube radius is at 50mm.
• No flush: Dynamic pressure is too weak, pipe work sizing is incorrect, or flush tube curve is 90°.
Note: do not grease inside the mechanism.
For the UK market only: Tel. 01491 821 821 - email: [email protected]