Installation manual: General installation diagram
2.2 Horizontal wall-mounted water heater
(25/40/65/80 L)
IMPORTANT: The SQUARE 75/100/150 L model is
wall-mounted only
Position the drilling template (printed on the packaging)
on the wall surface and mark the points corresponding to
the water heater model, ensuring the minimum clearance
spaces to be left around the water heater are respected
(see diagram E).
Drill and plug the water heater and use attachments of
at least 10 mm in diameter (Ø) suitable for your wall
type (drywall, concrete, brick).
Important: your wall must be able to bear the weight of
the water heater when fi lled.
Securely attach the support brackets, and use a rule to
check distances between the brackets. The elements used
for mounting must not protrude beyond the contact sur-
face with the water heater.
Lift and fi t your water heater against the bracket(s),
taking care to position the mountings on top of the
brackets (diagram F).
Lower the water heater until the mountings engage
in the notches. Once the mountings are engaged,
it will no longer be possible to slide the water heater
from side to side without exerting signifi cant force.
PLEASE NOTE: The cold water inlet and the hot water outlet must be positioned on the left.
The hot water outlet must be positioned upward.
Diagram E
400 mm
min.
The mounting brackets do not enable any confi guration other than those set out
in this manual. Using the brackets to attach the water heater to the ceiling
is strictly PROHIBITED.
6
CEILING
20 mm
min.
FLOOR
Bracket
Wall
YES
Water heater
Bracket
Wall
NO
Water heater
Diagram F
on
on
Indicative weight
of the filled
water heater
Range Capacity Mass
25 L
45 kg
40 L
70 kg
Flat
65 L
100 kg
80 L
120 kg
on