7.0 - TRANSPORT, STORAGE AND DISPOSAL
• During transport the material needs to be handled with care, avoiding any impact or vibrations to the device;
• If the product has any surface treatments (ex. painting, cataphoresis, etc) it must not be damaged during transport;
• The transport and storage temperatures must observe the values provided on the rating plate;
• If the device is not installed immediately after delivery it must be correctly placed in storage in a dry and clean place;
• In humid facilities, it is necessary to use driers or heating to avoid condensation.
• At the end of its service life, the product must be disposed of in compliance with the legislation in force in the country where
this operation is performed.
8.0 - WARRANTY
The warranty conditions agreed with the manufacturer at the time of the supply apply.
Damage caused by:
• Improper use of the device;
• Failure to observe the requirements described in this document;
• Failure to observe the regulations pertaining to installation;
• Tampering, modification and use of non-original spare parts;
is not covered by the rights of the warranty or compensation for damage.
The warranty also excludes maintenance work, the assembly of parts or non-original spare parts, making changes to the
device and natural wear.
9.0 - PLATE DATA
The rating plate data (see example provided here) includes the following:
• Manufacturer's name/logo and address (possible distributor name/logo)
• Mod.:
= device name/model followed
• Gas/air ratio:
= Gas/aria mixing ratio
• P1 max
= Maximum inlet pressure at which product operation is guaranteed
• P2
= Outlet pressure range
• TS
= Temperature range within which product operation is guaranteed
• year
= Year of manufacture
• Lot
= Product serial number (see explanation below)
• U1750
= Lot issued in year 2017 in the 50th week
• 28184
= progressive job order number for the indicated year
• 00002
= progressive number referring to the quantity of the lot
AGP/RC - AG/RC
by the connection diameter
Mod.: AG/RC DN 65
Gas/air ratio: 1/1-1/10
P2: 2-150 mbar
year: 2017
18
Madas Technical Manual - 4|4.5 - REV. 0 of 10
Via Moratello, 5/7 - 37045
Legnago (VR) - Italy
www.madas.it
P1 max: 500 mbar
TS: -15+60 °C
Lot:U1750
28184/00002
Oct 2018
th