16
-
The display reminds you that you have to open the milk dispensing spout (Fig. 39).
-
The display reminds you that you have to remove the AquaClean filter (Fig. 40).
2 Remove the drip tray and the coffee grounds container, empty them and put them back into place.
3 Remove the water tank and empty it.
4 Place a large container (1.5 l) under the coffee dispensing spout.
5 Pour the whole bottle of Philips descaler in the water tank and then fill it with water up to the CALC
CLEAN level (Fig. 41). Then place it back into the machine and press the OK button to confirm.
6 The first phase of the descaling procedure starts. The descaling procedure lasts approx. 30 minutes
and consists of a descaling cycle and a rinsing cycle.
7 Let the machine dispense the descaling solution until the display reminds you that the water tank
is empty.
8 Empty the water tank, rinse it and then refill it with fresh water up to the CALC CLEAN level
indication.
9 Remove and rinse the milk carafe. Fill it with fresh water up to the MIN level indication and reinsert
it into the machine. Then open the milk froth dispensing spout.
10 Empty the container and place it back under the coffee dispensing spout. Press OK to confirm.
11 The second phase of the descaling cycle, the rinsing phase, starts and lasts 3 minutes. The display
shows the rinsing icon and the duration of the phase.
12 Wait until the machine stops dispensing water. The descaling procedure is finished when the tick
appears on the display.
13 Press the OK button to exit the descaling cycle. The machine starts heating up and performs the
automatic rinsing cycle.
14 Clean the milk carafe after descaling (see 'Weekly cleaning of the milk carafe').
15 Clean the brew group after descaling (see 'Cleaning the brew group under the tap').
16 Place a new AquaClean filter in the water tank.
Tip: Using the AquaClean filter reduces the need for descaling!

What to do if the descaling procedure is interrupted

You can exit the descaling procedure by pressing the on/off button on the control panel. If the
descaling procedure is interrupted before it is completely finished, do the following:
1 Empty and rinse the water tank thoroughly.
2 Fill the water tank with fresh water up to the CALC CLEAN level indication and switch the machine
back on. The machine will heat up and perform an automatic rinsing cycle.
3 Before brewing any drinks, perform a manual rinsing cycle. To perform a manual rinsing cycle, first
dispense half a water tank of hot water and then brew 2 cups of pre-ground coffee without adding
ground coffee.
Note: If the descaling procedure was not completed, the machine will require another descaling
procedure as soon as possible.

Warning icons and error codes

Meaning of the warning icons

Fill the water tank with fresh
water to the MAX level
indication.
ADD WATER
The brew group is blocked by
coffee powder. Clean the brew
group.