ELECTRICAL
Check the proposed outlet to be used to insure that the voltage, phase, and current carrying
capacity of the circuit from the electrical panel correspond to the requirements of the cabinet.
NEVER use an extension cord to wire any unit. All inter-wiring between the electrical panel and the
unit must be done in accordance with the National Electric Code and all state and local codes.
Refer to the Serial Tag for all pertinent electrical information.
Observe all Warning Labels. Disconnect power supply to eliminate injury from electrical
shock or moving parts when servicing equipment.
Unit
Model
GSF-VT
GENERAL
The Grill Side Freezer employs a cold wall evaporator located inside the cabinet as the heat-
removing source. During the refrigeration process, heat is removed through the evaporator tubing
and transferred to the condensing unit on top of the cabinet, where it is expelled to the surrounding
outside air. It is extremely important to allow a four (4) inch clearance on the top, rear, and sides of
the unit for the refrigeration process to function properly.
The temperature controls for the three compartments are located in the back of the cabinet. A
cover, which is labeled, must be removed to access the temperature controls. There are three
controls. When looking in through the access opening, the control on the left is for the top
compartment, the center control for the center compartment, and the right control for the bottom
compartment. The controls monitor the temperatures of each compartment. If one of the
compartments becomes too warm, the control will activate the refrigeration cycle, which will cool all
three compartments. Any one of the controls can start the refrigeration cycle, however, the
compartments are not individually refrigerated.
The top two refrigerated compartments can be accessed from the top by sliding up the black
covers. The front doors of the compartments can also be opened by grasping the top edge, lifting
up, and allowing the door to set down by pivoting along its bottom edge. Opening the door in this
fashion will allow for easy loading. See the pictures above.
Type of
Connection
Cord with NEMA 5-20P plug
OPERATION
2
Voltage/Hz/Ph
See Serial Tag