Warranty Information - Eaton HDFS3P1 Manual De Instalación

Idiomas disponibles

Idiomas disponibles

ENGLISH
HDFS3P1 - INSTALLATION INFORMATION FOR HUMIDITY SENSOR AND FAN CONTROL
( For example: Press the fan button (1) time for High Humidity; (2) times
for Medium Humidity; (3) time for Low Humidity).
° After the last button is pressed the bi-color LED will flash
back the current setting for that function 10 times at
two-second intervals. If no selection had been made, the
device will exit programming mode.
STEP 3 : Enter Programming Mode
• Press and hold the fan button for eight seconds. The bi-color LED light
will flash 3 times and turn to white indicating that the settings are
saved and the load will turn OFF.
EXAMPLE
Programming Example: To change the humidity level of the switch from
high to medium, follow the steps shown below:
1. Press and hold the fan button for eight seconds. The bi-color LED light
will come on.
2. The bi-color LED light will now flash once every 2 seconds indicating
the current setting, which is at High Humidity.
3. Press the fan button two times to choose "Medium Humidity" the bi-col
or LED light will now flash two times every 2 seconds indicating the
new setting at "Medium Humidity"
4. Press and hold the fan button for eight seconds. The bi-color LED light
will flash 3 times and turn to white indicating that the setting is saved
and the load will turn OFF.

WARRANTY INFORMATION

EATON WIRING DEVICES LIMITED 2 YEAR WARRANTY Eaton Wiring Devices warrants its Humidity Sensor and Fan Control to be free of defects in materials and workmanship in normal use and
service for a period of two years from date of original purchase. THIS TWO (2) YEAR LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS, OR LIABILITIES, EXPRESSED OR
IMPLIED (INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS IN DURATION IN EXCESS OF TWO YEARS FROM THE DATE OF ORIGINAL
CONSUMER PURCHASE). NO AGENT, REPRESENTATIVE, OR EMPLOYEE OF EATON HAS AUTHORITY TO INCREASE OR ALTER THE OBLIGATIONS OF EATON UNDER THIS WARRANTY. To obtain
warranty service for any properly installed Eaton Humidity Sensor and Fan Control that proves defective in normal use send the defective Humidity Sensor and Fan Control prepaid and insured to
Quality Control Dept., Eaton Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269; in Canada: Eaton Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8. Eaton will repair
or replace the defective unit, at its option. Eaton will not be responsible under this warranty if examination shows that the defective condition of the unit was caused by misuse, abuse, improper
installation, alteration, improper maintenance or repair of damage in shipment to Eaton. EATON SHALL HAVE NO RESPONSIBILITY FOR INSTALLATION OF THE HUMIDITY SENSOR AND FAN CONTROL
OR FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR ANY SPECIAL, INCIDENTAL, CONTINGENT, OR CONSEQUENTIAL DAMAGES OF ANY KIND, RESULTING FROM DEFECTS IN THE HUMIDITY
SENSOR AND FAN CONTROL OR FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT. THE EXCLUSIVE REMEDY FOR BREACH OF THE LIMITED WARRANTY CONTAINED
HEREIN IS THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT AT EATON'S OPTION. IMPLIED WARRANTIES (IF ANY) INCLUDING, BUT NOT LIMITED TO IMPLIED WARRANTIES OF FITNESS
FOR A PARTICULAR PURPOSE AND MERCHANTABILITY, ARE LIMITED IN DURATION TO A PERIOD ENDING TWO YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE. IN NO CASE SHALL
EATON'S LIABILITY UNDER ANY OTHER REMEDY PRESCRIBED BY LAW EXCEED THE PURCHASE PRICE. Some states do not allow the exclusion or limitation of incidental or consequential damages or
allow disclaimers or modifications of or limitations on how long an implied warranty lasts, so the above limitations may not apply to you. Some Canadian provinces do not allow exclusion or variance
of implied warranties so that some or all of the above limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state
and province to province. Read enclosed instructions carefully. If you have any questions concerning use or care of this product, please write: Consumer Service Division, Eaton Wiring Devices, 203
Cooper Circle, Peachtree City, GA 30269.
TROUBLESHOOTING
The switch button is not functional:
Check if the device is wired properly. This device requires a NEUTRAL wire
for operation. Often the WHITE wire is used as a LOAD wire. Be sure to test
ALL wires. Also make sure that the HOT and LOAD wires are not reversed.
Press the Fan Button:
• If the load does not work and the indicator light is not on.
TURN OFF the power at the circuit breaker then check wire connections.
Confirm that the NEUTRAL wire is connected.
• If the Humidity Sensor does not turn on the fan.
Change the humidity level to match the appropriate condition or
manually turn ON the fan, after 20 minutes the humidity sensor will be
operational.
www.eaton.com
www.eaton.com/wiringdevices
EIS-0268-EFS (REV. A)
loading