Alcad SCM-051 Manual Del Usuario página 5

Ocultar thumbs Ver también para SCM-051:
V I D E O P O R T E R O
B
VISUALIZACIÓN IMAGEN EN TODOS LOS MONITORES - VIEWING THE IMAGE ON ALL THE MONITORS - VOIR L’IMAGE SUR
TOUS LES MONITEURS
Funcionamiento - Operation - Fonctionnement
It is possible to activate the monitor’s automatic switch-on system always providing that no other monitor is already in use (system
engaged). When the call is received, it rings on all the monitors. The image of the visitor is automatically shown on all the monitors of
this dwelling. If the receiver or any of the monitors is picked up, audio and video communication will be established on this monitor
with the visitor. If the handset of another monitor is picked up, you will hear beeping tones.
Maximum of 10 monitors per building with this type of connection. See page 6.
230V~
Next tap-off
B1B2 B1B2 B1B2 B1B2 B1B2 B1B2
Other
dwellings
Bus
SECTION TABLE
Up to 50 m -
A
2
H I L O S
-
2 - W I R E
18V
B1B2 B2B3
230V~
B1B2 B2 B3
DIV-054
cod.9730070
Connections bracket programmed first
Maximum of 4 monitors for each ALS-020
Before making the connections to the +/- terminals, program the connections brackets
V I D E O D O O R
E N T R Y
26
26
27
27
S2
S2
S5
S5
B2
B1
S Y S T E M S
-
V I D É O P O R T I E R
A
26
27
S2
S5
B2
B1
B1
All the monitors
2
F I L S
26
27
S2
S5
B2
B2
B1
loading