Care and Cleaning (cont.)
• Always test your cleaning solution on an inconspicuous area
before applying to the entire surface.
• Do not allow cleaners to sit or soak on the surface.
• Wipe surfaces clean and rinse completely with water immediately
after cleaner application. Rinse and dry any overspray that lands
on nearby surfaces.
• Use a soft, dampened sponge or cloth. Never use an abrasive
material such as a brush or scouring pad to clean surfaces.
For detailed cleaning information and products to consider, visit
www.kohler.com/clean. To order Care & Cleaning information, call
1-800-456-4537.
Troubleshooting
CAUTION: Risk of product damage. This product contains
sensitive electronic components. Use care not to damage pins and
connectors during troubleshooting.
CAUTION: Risk of product damage. Do not insert anything other
than the sensor wire into the sensor wire connector (phone jack) on
the circuit board.
NOTE: For service parts information, visit your product page at
kohler.com.
Faucet Troubleshooting Table
Symptoms
1.
No water flow.
1276182-2-C
Probable Causes
Recommended Action
A. The supply
A. Confirm that the
stops are
supply stops are open.
closed.
B. Handle is in
B. Rotate the handle to the
the closed
open position. Refer to
the "Faucet Operation"
position.
section.
C. The hot
C. Confirm that the
and/or cold
supply hoses are not
supply hose
kinked. If coiled,
is kinked.
maintain an inside
diameter (ID) of 3" (76
mm).