Kobalt SGY-AIR88 Manual Del Usuario página 4

Pistola atomizadora grande alimentada por gravedad
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

OPERATION INSTRUCTIONS
Proper handling of the gun is essential for obtaining a good finish. The gun should be held at a 90 angle to
the surface being covered, and moved parallel to it. For precise control of the gun and material, the trigger
should be released before the end of the stroke. Hold the gun 6 to 12 inches away from the surface
depending on material and atomizing pressure. For a uniform finish, lap each stroke over the preceding
stroke, making sure the spray is smooth and wet. Using the lowest possible atomizing air pressure will
reduce over spray and provide maximum efficiency. (See Fig. 6)
6
REPAIR INSTRUCTIONS FOR AIR DISTRIBUTION RING
CAUTION: Take care not to damage the seals on the gun body when
removing the air distribution ring.
1. Remove the nozzle set:
a. Remove air cap w/ring. (See Fig. 1)
b. Unscrew the fluid adjustment knob. (See Fig. 2)
c. Pull out needle spring and paint needle. (See Fig. 3)
d. Remove paint nozzle using wrench provided. (See Fig. 4)
1
2. Pull out the air distribution ring using a needle-nose pliers,
and remove dirt. (See Fig. 5)
NOTE: Make sure that dirt has not settled in the sealing surfaces and no
scratches prevent optimum sealing performance.
5
Even and wet coat
6 to 12 inches
Start
Pull
stroke
trigger
RIGHT
2
Light coat
Release
End of
trigger
stroke
3
4
Heavy coat
WRONG
4
O
Tabla de contenido
loading

Este manual también es adecuado para:

0301329