ICE BRIDGE SIZE ADJUSTMENT GUIDE:
! Press and hold the "ADJUST" button for at least 3 seconds, the unit will enter the ice size
adjustment process. The words "Ice Adjust" and "0 Minute" display on the LCD screen.
! While in the Ice Size Adjustment mode, press the "CLEAN" button or the "MODE" button for the
desired ice size.
Smaller ice setting:
By pressing the "CLEAN" button, you can decrease the thickness (depth) of the ice bridge by shorting the
ice making process time. Time can be changed from "-1 Minute" to "-6 Minutes". When the number -6
flashes, it indicates the smallest ice size status. If you press the "CLEAN" button again, it has no effect.
Larger ice setting:
By pressing the "MODE" button, you can increase the thickness (depth) of the ice bridge by extending the
ice making process time. Time can be changed from "1 Minute" to "10 Minutes". When the number 10
flashes, it indicates the largest ice size status. If you press the "MODE" button again, it has no effect.
After 10 seconds without any operation, the unit will automatically memorize the current status and return
to the previous process.
NOTE: During the ice size adjustment mode the words "Ice Adjust" and "0 Minute" display on the
LCD screen indicating the unit is in the regular (or middle) setting of the ice size. When the machine is
in the cleaning stage or ice full stage, the ice size adjustment mode can't be accessed.
IMPORTANT: The ice bridge adjustment has been set at the factory for optimum performance. The
ice adjustment procedure should be made by an authorized service technician. Recognize that the slab
ice bridge thickness might vary over time. A slight change in this set up is appropriate or necessary.
ADDITIONAL INFORMATION:
Replace Water Filter every 2,000 harvest cycles.
Clean Evaporator every 3,000 harvest cycles.
Clean Air Filter and Vacuum the Condensing Unit every 5,000 harvest cycles.