Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26

SETTING MENU

To access the Setting Menu:
1
Press and hold « START » for 5 seconds
Navigation
Battery Selection button: will select or modify the values of the sub
menus
NB. For the sub menu 'Timer': To modify the settings quickly, press and hold
2
Mode button: will access the next sub menu and confirm the sub
menu settings. The sub menus are displayed in the following order:
Language
Cables Testing
Press Start/Stop to confirm and exit the « setting » menu
3
In « Cables Testing » press Start/Stop to commence testing
Sub menu :
Language:
Change the display language.
Diag and Showroom:
This function allows the user to set up the voltage to be delivered whilst using the Diag or
Showroom functions up to 15.0V (nb: the default voltage setting is 13.5V)
Press the battery selection button quickly to increase the value of the voltage by 0.1V.
Press and hold the battery selection button to increase the value of the voltage by 0.5V
When you have reached the maximum 15V it will revert back to 12V.
Press Start to accept the required setting and exit the menu. To start using DIAG mode, follow the
steps of the Diagnostic mode listed on page. 13. To start using SHOWROOM mode, follow the steps
of the Showroom mode listed on page. 14.
Lock Showroom:
Locks the Showroom function, preventing activation of other modes.
Timer:
Maximum value : 24 hours (set on 00H to deactivate the function)
When the delay is set, press the Start/Stop button to start delayed charge.
Follow the instructions for the « charge » mode.
The display backlight will deactivate and the LEDs will turn off until the beginning of the charge
cycle. The display will show a count-down to the start of the charge
If a battery is not connected, the count-down will continue without being displayed. At the end of
the count the Gysflash will display "Connect Battery", and no current will be supplied until a
battery is connected. In case of polarity reversal, the Gysflash 75-12 HF will terminate the count-
down, restarting when the battery is connected correctly.
Cables Testing:
This mode must be used each time the output cables are changed. The Gysflash 75-12 HF is
compatible with 2 x 5m 16mm
1
To launch the cable check, press the Start/Stop button.
2
The message « Short circuit the clamps » is displayed
3
Put the clamps in short circuit for more than 10 seconds. When the clamps are in short circuit,
14
Diag
Lock Showroom
Charge End
Restart
2
cables.
Showroom
Timer
Tabla de contenido
loading

Tabla de contenido