Internal batteries and charging clamps
23
cm
Use: warning
In
rest
clamps must absolutely be placed on
their support and not on the handle
which could risk electrical arcs and
short circuits resulting in a highly
discharge of the battery.
Starter mode
12V Mode
or
or
24V Mode
or
Energy Station
Before any use, instal both « internal batteries » (not
provided) : 12V lead batteries with liquid or gel electrolyte of
a maximum capacity of 120 to 170 Ah each. Their
dimensions must not exceed 45x 53x23 cm, and 100 kg for
the total weight.
To install them:
Unplug the power supply cable or place the charging
switch on « 0 ».
Fasten the 4 collars supplied on the 4 cables.
Connect the batteries to the Energy Station respecting the
polarities:
- Red cable to the battery +
- Black cable to the battery –
position,
the
charging
•
Unplug the power supply cable or place the charging switch
on « 0 ».
•
Connect the cables to the battery outputs 1 or 2.
•
Connect the clamp to the battery of the vehicle to start
respecting the polarities.
•
By switching on the ignition key, you will activate the starter
function.
Nb : Your engine does not start, wait for 3 minutes between
2 starting attempts.
•
Charge the batteries after using. (see charger mode)
•
Unplug the power supply cable or place the charging switch
on « 0 ».
•
Connect the cables to the 24V output.
•
Connect the clamps on the vehicle battery to start respecting
the polarities.
YES
NO
10/40