Troubleshooting

Problem
The power plug (6) is connected to an
electrical outlet but the power indicator
(17) does not light up and the appliance
does not heat up.
After a while, the appliance stops
working.

Technical data

Operating voltage:
Power consumption:
Dimension (W x D x H):
Oil reservoir filling level:
Weight:
Operating voltage:
Power consumption:
Dimension (W x D x H):
Oil reservoir filling level:
Weight:
(IM)601-000170_MAKRO_Deep fryers_booklet_V2_210217.indb 71
Cause
The power plug (6) is not connected well.
The fuse of the power supply has been
triggered.
The control unit (4) is not installed correctly.
The overheating protection has been
activated.
The overheating protection has been
activated.
GDF3004
GDF3024
220 - 240 V ~ , 50/60 Hz
220 - 240 V ~ , 50/60 Hz
2500 W
2 x 2500 W
270 x 380 x 310 mm
490 x 380 x 310 mm
Min. 3.5 l
Min. 2 x 3.5 l
Max. 4 l
Max. 2 x 4 l
5.6 kg
10.2 kg
GDF5008
GDF5028
220 - 240 V ~ , 50/60 Hz
220 - 240 V ~ , 50/60 Hz
3250 W
2 x 3250 W
300 x 470 x 420 mm
600 x 470 x 420 mm
Min. 6.0 l
Min. 2 x 6.0 l
Max. 8 l
Max. 2 x 8 l
9.2 kg
16.5 kg
Solution
Unplug the power plug and re-plug it
properly.
Check the fuse. Try to connect the
appliance to another electrical outlet.
Check if the control unit (4) is at the
correct position. Reinstall the control unit.
Press the RESET button on the control
unit.
Press the RESET button on the control
unit.
GDF3008
220 - 240 V ~ , 50/60 Hz
3250 W
640 x 260 x 390 mm
Min. 6.0 l
Max. 8 l
7.40 kg
71
GDF3028
220 - 240 V ~ , 50/60 Hz
2 x 3250 W
640 x 550 x 390 mm
Min. 2 x 6.0 l
Max. 2 x 8 l
13.82 kg
21/2/17 4:02 pm