VDS POWER 1R0 Serie Manual Del Usuario página 6

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

GB
4. OPTIONS
ON
AUTOMATIC
1
2
3
4
5
6
CLOSING
ON
1
2
3
4
5
6
ON
DISABLE STOP
1
2
3
4
5
6
ON OPENING
ON
1
2
3
4
5
6
ON
RADIO OPEN/
1
2
3
4
5
6
ALTERNATIVE
ON
1
2
3
4
5
6
ON
1
2
3
4
5
6
DEAD MAN
ON
1
2
3
4
5
6
ON
DIGITAL
1
2
3
4
5
6
ENCODER
ON
1
2
3
4
5
6
If OPTION 3 & 4 ON, control unit makes a normal opening and dead man on closing
If OPTION 3 ON & OPTION 4 OFF, control unit makes dead man on opening and closing
5. TIME REGULATIONS
AUTOMATIC CLOSING TIME (GREEN)
Regulates the waiting time before
the automatic close. Turn LEFT to
-
+
decrease
and RIGHT to increase
Minimum - 6 to 8sec
Maximum - 110 secs
6. DIGITAL TIME PROGRAMMING for working and automatic closing.
PRESS
CLOSED DOOR
PROG. TIME
OPENING
WAIT
DOOR OPENED
PRESS OPEN/LIMIT SWITCH
DOOR CLOSED
POWER 1R0
Door closes automatically after
waiting the a.c.time.
7
8
9
10
Door does not close automatically.
7
8
9
10
Opening the alternative button is
disabled.
7
8
9
10
If alternative button is pressed door
stops.
7
8
9
10
Radio card / OPEN button works as
alternative button.
7
8
9
10
Radio card / OPEN button works as a
opener.
7
8
9
10
Enabled.
7
8
9
10
Disabled.
7
8
9
10
Enabled.
7
8
9
10
Disabled.
7
8
9
10
WORKING TIME (RED)
-
1.5s
FLASH
PROG.
TIME
PROG.
1 X
RELEASE
FLASH
START
PRESS OPEN/LIMIT SWITCH
FCC
START
DOOR
CONTACTS
SAFETY EDGE/
PHOTOCELL
PHOTOCELL
TEST
PRE-FLASHING
PROGRAMMATION
TYPE
Regulates the opening and closing
time. Turn LEFT to decrease and
+
RIGHT to increase.
Minimum - 6 to 8sec
Maximum - 85 secs
ON
TIME
LED ON
PRESS OPEN
FCA
AUTOMATIC
CLOSING
WAIT
PRESS OPEN
OFF
SAVE & EXIT
LED OFF
ON
Normally open door contacts
1
2
3
4
5
6
7
8
9
10
ON
Normally close door contacts
1
2
3
4
5
6
7
8
9
10
ON
Input 21-22 configured as resistive
8k2.
1
2
3
4
5
6
7
8
9
10
ON
Input 21-22 configured as
mechanical (N.C)
1
2
3
4
5
6
7
8
9
10
ON
Enabled.
1
2
3
4
5
6
7
8
9
10
ON
Disabled.
1
2
3
4
5
6
7
8
9
10
ON
Flashing output ENABLED before
starting, open and close
1
2
3
4
5
6
7
8
9
10
Flashing output DISABLED before
ON
starting, open and close
1
2
3
4
5
6
7
8
9
10
ON
Digital time programming.
1
2
3
4
5
7
8
6
9
10
ON
Maneuvre time with potentiometers.
1
2
3
4
5
7
6
8
9
10
INVERSION TIME (WHITE)
-
+
START
DOOR OPENING
START
DOOR CLOSING
The maximum time memorization is 2 min. After which, the
operation will end and that limit is memorized.
If programming is activated, but any maneuver is made after 1
minute, programming is deactivated.
Regulates the inversion time.
Trun LEFT to decrease and
RIGHT to increase.
Minimum - 0.5 seg
Maximum - 7.5 seg
CLOSING
WAIT
2 - 4
Tabla de contenido
loading

Este manual también es adecuado para:

Power k 1r0Power i 1r0Power gi 1r0Power im 1r0Power gim 1r0

Tabla de contenido