TANK CLEANING
For the cleaning operations proceed as follows:
1) Remove the product and the shelves from the tank.
2) Unplug the unit.
3) Remove the frontal grid uscrewing fixing screws and extract the
flexible discharge tube.
4) Put below a tray for draining water.
5) Remove the internal draining plug.
6) Clean and dry the interior of the tank with a soft cloth, using neutral soap.
7) Reset the water discharge tube, the grid and the plug inside; switch
on the unit with the lights off; after 1 hour the cabinet is ready to preserve your products again.
Do not use jet of water to clean the cabinet: electrical wiring can have damages.
Never use mechanical devices or any other means to accelerate the defrosting process, other than
those recommended by the manufacturer.
DOOR REGULATION
This unit is equipped with sliding doors.
The levelling operation is very important: a bad levelling
can cause a fold of the door frames when the loading ope-
ration is finished.
The cabinet must be installed on an even surface; it is neces-
sary to settle the sliding doors so that they will be parallel.
In order to do this you can adjust the wheel on the bottom
(A-B); for example if there is a gap upwards you can raise
the wheel A or pull down the wheel B.
To adjust a wheel it is necessary at first to unscrew the screw
Nr.1; than you can screw down or unscrew the screw Nr. 2
if you want to pull down or to raise the wheel.
When the desired position is reached screw down the screw
1 again.
To remove the door, you must unscrew the upper lines; push
up the door and extact it.
INFORMATIONS ABOUT SERVICE
REAR HANDLES MOUNTING
In order to obtein a right working of the cabinet, it's
necessary to mount on the rear side two handles A fixed
by screws B 5.5x16 TEFR.
The handles can be use either to move the cabinet or
as spacer from the wall.
-11-