Personal Protective Equipment (Ppe); Technical Data - Binzel Abicor PP Instructivo De Servicio

Mig/mag antorcha de soldadura
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3 Technical Data

2.3 Personal protective equipment (PPE)

3 Technical Data
Ambient temperature of welding
Transport and storage
Relative humidity
Control device rating
Tab. 1
General Data
Type of voltage
Polarity of the electrode
Wire types
Type of use
Voltage rating
Protection type of the machine-side connections
Shielding gas (DIN EN ISO 14175)
Tab. 2
General torch data according to EN 60 974-7
Type
Type of cooling Load*
PP
24D
air
36D
air
240D liquid
401D liquid
Tab. 3
Product-specific torch data as laid out in EN 60974-7 PP
EN - 4
• Occupational health and safety regulations of the country in question. For
example, Germany: Protection Law and the Company Safety Ordinance.
• Regulations on occupational safety and accident prevention.
To avoid danger to the user, these instructions recommend the use of personal
protective equipment (PPE).
This consists of protective clothing, safety goggles, a class P3 respiratory mask,
protective gloves, and safety shoes.
ED
Wire ø
CO
M21
2
(A)
(A)
(%)
(mm)
230
200
35
0.8 - 1.0
290
260
60
0.8 - 1.2
270
240
100 0.8 - 1.2
350
320
100 0.8 - 1.6
*For pulse arc welding, the load data are reduced by up to 30%.
- 10 °C to + 40 °C
- 25 °C to + 55 °C
up to 90 % at 20 °C
1 A AC / 250 V AC
DC direct voltage
Usually positive
commercially available round wires
manual
113 V peak value
IP2X , IP3X (EN 60 529)
CO
and mixed gas M21
2
Gas flow rate
Flow temp. Flow
max.
(l/min)
(°C)
10 - 18
10 - 18
10 - 20
50
10 - 20
50
PP
Cooling data
Flow pressure
min.
min.
max.
(l/min) (bar)
(bar)
1
2.0
3.5
1
2.0
3.5
Tabla de contenido
loading

Tabla de contenido