T&S Safe-T-Link Instrucciones De Instalación Y Mantenimiento página 6

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

General Instructions
2. If pipe tee is female, fi rst apply Tefl on tape or pipe joint compound to threads of pipe
nipple (not supplied), and thread pipe nipple into female pipe tee. Then thread (gas) no.7
valve onto pipe nipple and tighten.
3. For "Vertical" or "Combination" loop
installations, attach no.5 (male/female elbow)
as shown to no.7 valve with Tefl on tape or
pipe joint compound.
4. Apply Tefl on tape or pipe joint compound
to male threads of no.4. Thread no.4 into no.7
valve or no.5 and tighten.
Appliance Side without Quick Disconnect
or Quick Disconnect Valve (Safe*T*Guard)
1. For chosen loop installation, attach
no.6 (female/female elbow) to the male
appliance stub-out with Tefl on tape or
pipe joint compound.
2. Thread male end of no.4 into no.6
(female elbow) at appliance and tighten.
Appliance Side with Quick Disconnect or Quick Disconnect Valve (Safe*T*Guard)
1. For chosen loop installation, attach no.5 (female/female elbow) to the male appliance
stub-out with Tefl on tape or pipe joint compound.
2. Separate no.8a or 8b coupling. No.9 nipple (male) half will remain attached to no.4
fi tting. No.10 coupling (female) half will remain attached to no.1.
3.Apply Tefl on Tape or pipe joint compound to threads of no.4 fi tting. Thread male end of
no.4 into female elbow at appliance and tighten.
4. Reconnect no.8a or 8b coupling to nipple.
Finishing
1. Check tightness of all connections and perform leak test.
2. After installation of no.8a or 8b coupling, carefully push appliance back to operating
position and check that no.1 is not kinked, overbent, or caught under appliance casters.
Set length of no.11 so no.1 is never fully extended.
3. Affi x Orange label "Installation Instruction for Heavy-Duty Gas Connector" to back
of appliance after installation. Affi x Yellow label to wall near no.7 or equivalent valve.
Installation:
Safe Safe-T-Link Gas Connectors without SwiveLink Fittings
General
Follow General Step 1 through 5 on page 5.
Review the Installation Comparision diagram on the following page.
WARNING: No.8a or 8b must be
oriented so fl uid enters no.10 coupling
half and exits no.9 nipple half. Follow
fl ow direction arrows marked below
and on no.10 itself.
10
Coupling Half
(female)
Gas Flow Direction
6
9
Nipple Half
(male)
Tabla de contenido
loading