Craftsman 919.167281 Manual Del Propietário página 13

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

For replacement parts contact:
Air Compressor Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank
pressure above that required at the air
outlet.
Check Valve: When the air compres-
sor is operating, the check valve is
"open", allowing compressed air to
enter the air tank. When the air com-
pressor reaches "cut-out" pressure,
the check valve "closes", allowing air
pressure to remain inside the air tank.
Check Valve
Pressure Release Valve: The pres-
sure release valve located on the side
of the pressure switch, is designed
to automatically release compressed
air from the compressor head and the
outlet tube when the air compressor
reaches "cut-out" pressure or is shut
off. The pressure release valve allows
the motor to restart freely. When the
motor stops running, air will be heard
escaping from this valve for a few
seconds. No air should be heard
leaking when the motor is running or
after the unit reaches "cut-out"
pressure.
For replacement parts contact:
www.allpartsinc.com
Pressure
Release
Valve
13 - ENG
www.allpartsinc.com
Motor Overload Protector: The
motor has an automatic reset ther-
mal overload protector. If the motor
overheats for any reason, the overload
protector will shut off the motor. The
motor must be allowed to cool down
before restarting. The compressor will
automatically restart after the motor
cools.
How to Use Your Unit
How to Stop:
1.
Set the On/Auto/Off lever to
"OFF".
Before First Start-up
Risk of Unsafe
Operation. Serious
damage may result if the following
break-in instructions are not closely
followed.
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor pump has been replaced.
1.
Make sure the On/Auto/Off lever
is in the "OFF" position.
NOTE: If quick connect is installed,
pull coupler back until it clicks to
prevent air from escaping through the
quick connect.
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Installation section of this manual.)
3.
Open the drain valve fully
(counterclockwise) to permit air to
escape and prevent air pressure
build up in the air tank during the
break-in period.
NOTE: Always drain tank on a wash-
able surface or in a suitable con-
tainer to prevent damaging or staining
surfaces.
1-877-475-5660
A17893
1-877-475-5660

Capítulos

Tabla de contenido
loading

Tabla de contenido