a way that an incorrect connection is not possible. Secure all
connections with the corresponding union nut.
Connect the driver (power supply) to the mains after all parts
have been connected.
Never install the driver (power supply) inside an aquarium
hood, in the aquarium cabinet or above the water level! Al-
ways ensure the driver is adequately ventilated.
5 Operation
5.1 The IR remote control
With the IR remote control you can steer the various functions of
the JBL LED SOLAR lights. The remote control works the same
way as remote controls for TV etc. The IR receiver needs to be
installed near or at the aquarium cabinet so that the IR waves of
the remote control can reach it. All remote controls work with
the same wave length.
Pull the insulation strip off the battery compartment before the
initial use.
When using JBL LED SOLAR NATUR:
• ON/OFF at the touch of a button.
• Choice between the light colours Warm White (2700 K), Day-
light White (4000 K) and Cool White (6700 K). For ideal plant
growth we recommend Daylight White (4000 K).
• The light intensity can be adjusted in 8 steps. For the initial
change from fluorescent tubes to LED lighting we recommend
starting with about 50 % of the maximum light intensity and
increasing this by one step every 1 to 2 weeks.
When extending the system with JBL LED SOLAR EFFECT:
In addition to the features mentioned above:
• You can steer the colour channels Red, Green and Blue and
their mix with the buttons R+/R-, G+/G- and B+/B-.
• You can dim the colour channels in 7 steps.
5.2 Operation with a timer (not included):
The JBL LED SOLAR lights can be switched on and off with a
standard timer. The setting, chosen by remote control, is re-
tained when the timer is switched off and the lighting will start
with this setting the next morning.
5.3 Control via app und wifi: JBL LED SOLAR CONTROL WiFi
(available as accessory)
The IR receiver is replaced by the control unit JBL LED SOLAR
CONTROL. Its corresponding smartphone app can be downloa-
ded in the stores free of charge.
• Natural sunrises and sunsets, cloud simulations with light-
ning effects.
• Various preset programs of popular aquarium biotopes can be
selected.
• Individually programmable
6 Maintemance
Please disconnect the mains plug of the driver (power sup-
ply) for all maintenance work.
Do not use any hard items or aggressive cleaning agents for
cleaning.
Remove any limescale from the bottom of the light with a JBL
WishWash cloth, moistened with JBL Clean A, once a week.
12
If required, remove dust and other deposits from the top of the
light with a lint-free dry cloth.
7 Troubleshooting
LED light does not work
Possible cause:
Mains plug of driver (power supply) not connected to the mains.
Action:
Insert the mains plug into a mains socket.
Possible cause:
A connecting plug between driver (power supply) and light is
loose or has a poor contact.
Action:
Check all plug connections between the light and driver (power
supply) and ensure they are fitted correctly with a union nut,
tightened by hand.
Possible cause:
The light has been switched off with remote control.
Action:
Press the ON/OFF button of the remote control.
In the event of any other problem please contact the JBL Custo-
mer Support: https://www.jbl.de/support/
8 Technical data
JBL LED SOLAR NATUR:
LED module
operating voltage
CRI (full spectrum)
beam angle
service life
insulation class
JBL LED SOLAR EFFECT
LED Modul
operating voltage
beam angle
service life
insulation class
The lights have protection class III (protective low voltage).
Further technical data see page 100.
9 Manufacturer Guarantee
In addition to the legal claims of the customer against the
seller the guarantee covers the delivery of goods which are
free of defects and doesn't affect the statutory claims for
defects in accordance with § 437 BGB.
We, JBL GmbH & Co. KG Dieselstr. 3, 67141 Neuhofen, Germa-
ny offer the end user a guarantee of 2 years from the date of
purchase for functionality and absence of defects for the pro-
ducts listed below.
DE
UK
FR
NL
IT
SE
ES
PT
CZ
PL
RU
24 V DC
GR
85
120°
>50000 h
RO
IP 67
TR
24 V DC
120°
>50000 h
CN
IP 67