Master DH 731 Manual De Instruciones página 21

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
GB
1. HOW IT WORKS (Fig. 1.)
1. Cold refrigerant coil
2. Moist saturated air
3. Microswitch
4. Water tank
This product is a dehumidifier. It controls relative humidity by
passing the air through the unit, forcing the excess moisture to
condensate over the cooling elements. Contact with this cold
surface causes the moisture in the air to condense. This
condensed water then drains safely into the water tank. The dried
air then passes through the condenser where it is slightly warmed
and re-enters the room at a slightly elevated temperature.
2. WHERE TO POSITION (Fig. 2.)
Excess moisture will travel throughout your home, in the same
way that cooking smells waft to every room in the house. For this
reason, the dehumidifier should be positioned, so that it can draw
this moist air towards it from all over the home.
Alternatively, if you have a serious problem in one area you can
begin by positioning the dehumidifier close to this area and later
moving it to a more central point. When positioning the
dehumidifier, ensure that it is placed on a level surface and that
there is a minimum of 10 cm (4") of space on either side of the
unit to allow for efficient airflow. This dehumidifier is fitted with
castors for extra mobility, if you move the unit, it should first be
switched off and the water tank emptied. We do not recommend
the use of an extension lead, so please try to ensure that the unit
is sufficiently close to a fixed mains socket. If it is necessary to
use am extension lead, please ensure the diameter of the wires
of the cable is at least 1 mm
operation, outside doors and windows should be closed when
necessary for most efficient use.
3. BEFORE USE
Caution!
• Always keep the unit in vertical position.
• Leave the unit to stand for one hour before connecting to the
mains supply after transport or when it has been tilted (e.g.
during cleaning).
• Keep all foreign objects away from the air intake or output
openings.
• The mains supply must conform to the specification shown on
the rating plate at the back of the unit.
• If the supply cord is damaged, it must be replaced by an
approved service representative or a similar qualified person
in order to avoid a hazard.
• Never use the plug to start and stop the unit. Always use
switch on the control panel.
• Before moving the unit, first switch off, then unplug and empty
the water tank.
• Don't use bug sprays or other flammable cleaners on the unit.
• Never pour or spray water over the unit.
• THIS APPLIANCE IS NOT INTENDED FOR USE BY
PERSONS (INCLUDING CHILDREN) WITH REDUCED
PHYSICAL , SENSORY OR MENTAL CAPABILITIES, OR
LACK OF EXPERIENCE AND KNOWLEDGE , UNLESS
THEY
HAVE
BEEN
INSTRUCTION CONCERNING USE OF THE APPLIANCE
BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT
THEY DO NOT PLAY WITH APPLIANCE.
IMPORTANT!
Do not use this unit at ambient temperatures below 5ºC, to
prevent the possibility of a heavily ice up evaporating coil.
4. PARTS (Fig. 3.)
1. Front Plate
2. Control Panel
3. Air Outlet
4. Handle for the unit
5. OPERATION (Fig. 4.)
1. Control Panel
2. Fan Speed Switch
3. Power Indicator
5. Compressor
6. Dry warmer air
7. Fan
8. Warmed coil
2
. When the dehumidifier is in
GIVEN
SUPERVISION
5. Power cable
6. Filter inlet
7. Main housing
8. Water tank
9. Castors
4. Water Full Indicator
5. Humidistat Controller
Turning ON/OFF
1. Plug the unit into a correct mains socket. (Please refer to the
rating label at the rear of the unit for correct voltage/frequency.)
2. Set the humidity controller to required humidity level (the
intensity of the humidity extraction is increased clockwise). For
continuous working, pls set the humidistat to position 'MAX'.
3. To turn off the unit, set the humidity controller to position 'OFF'.
Setting ventilation speed
This dehumidifier features 2 speed fan.
either one of:
High Speed;
Setting Humidistat
1. Humidity controller from OFF – MAX.
2. Set the humidistat (humidity controller) to
required humidity level(the intensity of humidity
extraction is increased clockwise).
For continuous working, set the humidistat to
position 'MAX'.
6. DRAINAGE
While the water tank is full, the compressor will stop for self-
protection and the water full indicator will turn into red.
To move the water tank, pull it out squarely from the unit by using
the handle at the water tank (Fig. 9. ).
After empting the water tank, place the water tank into space.
Make sure it is properly positioned, in order for the 'water full' sign
to go out and your dehumidifier is operating.
Please note:
• Do not move & destroy the float of water tank, or the
machine will not able to operate.
• in case, the water tank has not been positioned well, the
water full indicator will turn into red.
Continuous drainage
To set the unit up for continuous drainage with the following
procedures:
1. Remove the water tank.
2. Position the spout as shown in the diagram (Fig. 5).
A. Spout for
continuous
drainage.
* The unit will not operate without the water tank, unless the
spout is properly positioned.
3. Place one end of an appropriately sized drain pipe over the
spout.
4. Place the other end of the pipe in a drain, ensuring it is not
coiled.
7. MAINTENANCE
Always unplug the unit from the mains before carrying out any
maintenance or cleaning of the unit.
CLEANING THE BODY
Use soft cloth to wipe the unit clean.
Don't
ever
use
chemically treated clothes, or other cleansing solutions. These all
could possibly hurt the cabinet.
CLEANING THE AIR FILTER (Anti-Dust Filter)
• Remove the water tank & extract the filter holder. (Fig. 6.)
OR
• Use a vacuum cleaner or tap the filter lightly for easy
cleaning. If the filter is particularly dirty, use warm water with a
small amount of medium strength. (Fig. 7.)
• Make sure the filter is completely dry before replacing.
• Do not expose the filter to sunlight.
STORAGE
If not use the unit for an extended period of time. Please:
• Turing the unit off, unplug and tidy AC cord.
• Completely empty the water tank and wipe it clean.
• Cover the unit and store where it will not receive direct
sunlight.
8. TROUBLE SHOOTING
THE UNIT DOES NOT OPERATE:
• Is the unit plugged in?
• Is the house electricity on?
• Is the room temperature below 5
then it is out of the working range of the unit.
• Ensure the ON/OFF switch is turned on.
• Check the water tank is positioned properly in the unit and it is
not full.
Press the button on
Low speed.
B. ‚Water full' cutout
switch depressed when spout
for continuous drainage is fitted.
volatile
chemicals,
gasoline,
o
C or above 35
detergents,
o
C? If so,
loading