2) Unscrew the fixing washer in an anti-clockwise direction and then remove the white disc and the plate.
E
N
3) Using a flat-blade screwdriver, shut off the water by tightening the screws located on the check valve
G
caps clockwise.
24
4) Remove the white plastic ring, the temperature limiter, and then remove the friction washer as well.
5) Unscrew the cartridge using a 24 mm spanner and remove it from the mixer tap body.