17.

LEAVING THE SYSTEM UNUSED FOR LONG PERIODS OF TIME

What to do

MAINTENANCE

18.
Safety
instructions
Authorised
maintenance
personnel
Measures to
be taken
This manual is the property of PIUSI USA, Inc. Any reproduction, even partial, is forbidden.
Whenever it is thought that the system will remain unused for at
least 15 days, it must be emptied in order to prevent the product
from crystallising inside� This shall be followed by a washing
cycle�
The dispensing system was designed and built to require a
minimal amount of maintenance�
Before carrying out any maintenance work, disconnect the
dispensing system from any electrical and hydraulic power
source�
During maintenance, the use of personal protective equipment
(PPE) is compulsory�
In any case always bear in mind the following basic
recommendations for a good functioning of the pump�
All maintenance must be performed by qualified personnel�
Tampering can lead to performance degradation, danger to persons
and/or property and may result in the warranty being voided.
Whenever there is risk of frost, empty the circuit and the pump, taking
care to place the pump in an environment where the temperature is
no lower than 32°F / 0°C�
Check that the labels and plates found on the dispensing system do
not deteriorate or become detached over time�
ONCE A WEEK:
¦ check that the pipe connections are not loose to prevent any leaks;
¦ check and keep the filter installed on the suction line clean�
ONCE A MONTH:
¦ check the pump body and keep it clean and free of any impurities;
¦ check that the electrical supply cables are in good condition�
19/124