OPERATION
• Press the push-button control to open the valve.
• Mixer: temperature control via the side lever, with maximum temperature
limiter which can be adjusted.
• Automatic shut-off after ~7 seconds for washbasins (+/- 3 seconds
at 3 bar), ~3 or 7 seconds for urinals (depending on the model)
and ~30 seconds for showers (-10/+5 at 3 bar).
INSTALLATION
• Tap: supply with cold water (insert the blue or grey marker) or mixed water
(insert the red marker).
• Mixer: supply with cold water and hot water at 50°C (maximum
recommended 70°C), and balance the pressure between the hot
and cold water (ΔP < 1 bar). Maximum supply pressure is 10 bar
(we recommend 1 to 5 bar dynamic pressure).
• Shower and urinal models: respect the direction of the water flow,
see arrow on the valve body.
THE INSTALLER MUST ENSURE:
•
THE SEAL AROUND THE RECESSING HOUSING IS WATERPROOF
TO PREVENT ANY INGRESS OF WATER;
•
ANY WATER ACCIDENTALLY ENTERING THE RECESSING HOUSING
(E.G. CONDENSATION, RUN OFF, LEAKS, ETC.) HAS AN EXTERNAL
DRAINAGE POINT TO PREVENT ANY STAGNATION;
•
THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL
WALL PLATE AND THE WALL OR THE WALL PLATE AND THE VALVE
AT LEAST ONCE A YEAR, AND MAKE GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL
SUPPORT UK: 01491 821821. ALL OTHER MARKETS: +33 (0)3 22 60 22 74.
EN