Motores tubulares 45 mm con final de carrera electronico
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

06. LIMIT SWITCH PROGRAMMING
In the case of installation of several motors, must be programmed (and therefore powered) one motor at a time.
The installation must be carried out by a qualified technician. Before starting to work on the motor, carefully read the installation procedure. In case
of doubt, contact your supplier.
Installation must be performed using an ARCO, VISIO, KORT, KUADRO, FLUTE or equivalent transmitter. Before starting the installation, read the
transmitter instruction manual and identify the UP, STOP, DOWN, PROG buttons necessary for motor programming.
WARNING:
if possible, always install the roller shutter in such a way that at least one of the two limit switches is learned by "pressing" on the lower stop (anti-lifting devices) or
on the upper stop (stopper). The learning of at least one limit switch for "pressure" allows the motor to automatically compensate for variations due to the
adjustment of the blind and other possible factors of error. Periodically check the status of the roller shutter and (if present) of the locking devices that delimit the
limit switches (anti-lifting devices, stopper). If a limit switch is learned by "pressure", the motor will search the pressure point during normal operation. For this
reason, once the stroke has been programmed, it is forbidden to remove any locking devices that delimit the limit switches. In order to do not stress the pressure
points too much, choose a motor with power not higher than enough to move correctly the roller shutter.
The motor provides the possibility to program the limit switches according to 4 different modes:
1. roller shutter without anti-lifting devices and without stopper (see section 6.1)
2. roller shutter with anti-lifting devices and without stopper (see section 6.2)
3. roller shutter without anti-lifting devices and with stopper (see section 6.3)
4. roller shutter with anti-lifting devices and with stopper (see section 6.4)
NOTE: as long as the motor does not have a valid stroke in memory, you can move the motor in "hold-to-run" using the command buttons.
To continue with the installation, it is necessary to disconnect the motor and follow the procedures described.
06.1 ROLLER SHUTTER WITHOUT ANTI-LIFTING DEVICES AND WITHOUT STOPPER
Connect the power supply.
1-
Press PROG briefly (within 1 minute).
2-
The motor makes a signal
Press briefly UP.
3-
If the motor moves downward return to point 2,
if the motor moves upward go to point 4.
Bring the roller shutter in an intermediate position,
4-
keeping pressed UP or DOWN.
Press STOP briefly 3 times and wait.
5-
The motor moves downward
Stop the motor in the desired position by pressing STOP.
6-
Press PROG briefly.
7-
If you want to make a fine adjustment of the limit switch press UP or DOWN
(motor moves in small steps)
Press PROG briefly.
8-
The motor moves upward
Stop the motor in the desired position by pressing STOP.
9-
Press PROG briefly.
10-
If you want to make a fine adjustment of the limit switch press UP or DOWN
(motor moves in small steps)
Press PROG briefly.
11-
The motor signals DOWN-UP. End of the installation!!
ON
Prog
3x
Prog
Prog
Prog
Prog
03
Go to point 4
Repeat point 2
Only if fine adjustment is necessary
Only if fine adjustment is necessary