TEST EYEWASH UNIT
1. After completing installation, test the eyewash
station for proper operation by pulling down the
tray. Check for proper water flow and quickly close
the tray. Visually inspect the eyewash unit weekly
for cleanliness and proper solution level (per ANSI
Standard Z358.1-2014). When the water level drops
below the 15-minute fill line, the tank must be
emptied and then refilled. (See Figure 3)
2. Attach the eyewash inspection tag (included) to
the eyewash unit. This tag is to be used for weekly
inspection documentation. Hook-and-loop fasteners
are provided to attach the tag to the unit.
3. If the eyewash unit is not working properly, remove
it from the hazard area and contact Uline
immediately.
OPERATE EYEWASH UNIT
1.
Pull down the tray.
2. Hold eyelids open with thumbs and forefingers.
Rotate eyes back and forth to ensure a complete
rinse.
3. Allow water to bathe both eyes simultaneously for a
minimum of 15 minutes.
4. Seek medical attention immediately after use.
CAUTION! Do not lean on the eyewash tray
when in the opened position. Damage to unit
may result.