PORTA STREAM II
WARNING: Failure to comply with all instructions
and precautions stated in this manual may
result in serious personal injury, serious illness,
blindness or death.
• The Porta Stream II must be level for proper
operation.
• The unit may weigh over 150 lbs. when filled with
solution. Assistance may be required when installing
unit on the hanging bracket.
• Do not add any product or material to the solution
of saline concentrate and water.
• Employees must be instructed in the use of
emergency eyewash stations.
PORTA STREAM II LOCATION
The ANSI Standard Z358.1-2014 requires that:
1. The Porta Stream II shall be positioned with the
nozzle(s) no less than 33" and no greater than 53"
from the floor and 6" minimum from the wall or
nearest obstruction.
2. Eyewash units shall be in accessible locations that
require no more than 10 seconds to reach. The
eyewash shall be located on the same level as
the hazard, and the path of travel shall be free of
obstructions that may inhibit the immediate use of
the equipment. For a strong acid or a strong caustic,
the eye wash should be immediately adjacent to
the hazard.
3. Each eyewash location shall be identified with a
highly visible sign positioned so the sign is visible
within the area served by the eyewash. The area
around the eyewash shall be well lit.
PAGE 1 OF 9
1-800-295-5510
uline.com
SAFETY INFORMATION
LOCATION AND INSTALLATION
4. The eyewash station must be installed in an easily
The Porta Stream II may be placed on any level surface of
required height, such as a table or bench. Be sure to allow
for proper drainage and disposal of the flushing solution.
The unit may also be mounted on a wall or post using
the metal hanging bracket. The unit must be level for
proper operation.
INSTALLATION
At least two fasteners are required for the Porta Stream II
hanging bracket and are not included. The installer
must select fasteners that provide support for the
filled unit (approximately 150 lbs.) and the force of an
individual leaning on the unit when in use. The fastener
selection should also be determined by the type of
mounting surface support at that site.
Pour le français, consulter les pages 7-9.
• This emergency eyewash unit is intended for
emergency use by victims of eye contamination
until medical treatment is obtained. In all cases, the
victim should seek medical attention immediately
after flushing.
• An individual or department must be assigned the
task of checking all self-contained eyewash units on
a weekly basis.
• All eyewash devices containing saline should be
cleaned and refilled per solution manufacturer's
recommendations. Units containing just water need
to be cleaned and refilled at least once a week.
• Use of a fluid beyond the expiration date may result
in serious personal injury.
accessible location in the immediate area of
hazard to the employee.
Para Español, vea páginas 4-6.
0719 IH-1142
Tabla de contenido
loading

Resumen de contenidos para Uline Porta Stream II

  • Página 4: Información De Seguridad

    Se requieren al menos dos cinchos para el soporte del equipo. En el caso de un ácido fuerte o un para colgar del Porta Stream II que no se incluyen. El cáustico fuerte, la estación lavaojos deberá estar instalador deberá elegir cinchos que ofrezcan el ubicada justo al lado del peligro.
  • Página 5: Continuación De Ubicación E Instalación

    60.5 litros (16 galones) de solución necesarios para 5. Repita los pasos 3 y 4 agregando suficiente agua y llenar la unidad Porta Stream II, necesitará 54.8 litros (14.5 solución salina para mezclar aproximadamente un galones) de agua para mezclar con los 5.3 litros (180 total de 60.5 litros (16 galones) de solución.
  • Página 6: Continuación De Funcionamiento

    CONTINUACIÓN DE FUNCIONAMIENTO 3. A continuación, la persona lesionada deberá 5. Tras el enjuague, solicite atención médica bajar la cabeza hacia la unidad Porta Stream II, inmediata. acercándola a las manos. 6. El personal de seguridad y supervisión deberá 4. Cuando los ojos estén en el contacto con el ser notificado cuando se haya utilizado la flujo, use el pulgar y el índice de cada una de...

Este manual también es adecuado para:

H-1142S-9876

Tabla de contenido