CONNECT DUCTWORK
Ductfree Configuration
1. Use screws and wall anchors
(supplied) to secure the flue
mounting bracket to wall or ceiling
as shown.
2. Turn upper flue section upside
down so air vents are at the top.
Slide upper flue section into lower
flue section.
3. Snap the duct connector of the
ductfree plenum into the hole in
the bottom of the ductfree plenum.
Connect the ductfree plenum to the
upper flue section with (4) flat-head
screws (supplied).
4. Measure the distance from the top
of the duct connector to the ceiling. Cut a length of 6" round metal duct 6"
shorter than this dimension.
5. Fit duct section over the duct connector of the ductfree plenum. For best fit,
make sure duct seam is toward the front.
6. Set duct/flue assembly on hood with top tilted away from wall. Reach around
flue to engage bottom of duct with duct connector on hood. Tilt flue up against
wall. Duct seam can be cut to length if necessary.
7. Raise upper flue section and screw it to flue mounting bracket with (2) screws
(3.9x9.5mm). Screw lower flue section to hood with screws (3.9x9.5mm).
DUCTFREE FILTER
INSTALLATION
DuctfreeConfiguration Only
1. Purchase a ductfree filter kit (model no.
FILTERK3490CM or FILTERK3448") from
your dealer.
2. Remove the grease filters : at the handle,
push the stop inwards and pull the filters
downwards.
3. Holding the ductfree filter on its side,
insert one of the support rods, into the
upper groove in back that runs parallel
with the front of the hood, in order to avoid
that the filter might be sucked onto the
motor.
4. Fold the filter and insert it into the front,
upper groove.
5. Install the other support rods beneath
filters.
6. Replace the grease filters.
;;;;;
UPPER
FLUE SECTION
DUCTFREE
PLENUM
DUCT
CONNECTOR
OF THE
DUCTFREE
PLENUM
LOWER
FLUE SECTION
6" ROUND
METAL DUCT
DUCT
CONNECTOR
DUCTFREE
- 8 -
FLUE MOUNTING
AIR
BRACKET
VENTS
(in upper flue section)
DUCT
SEAM
GROOVES
SUPPORT
FILTER
ROD
SUPPORT
ROD
MEASURE