Oil Change; Air Filter Maintenance - Speedaire Lubricacion por aceite Serie Manual De Instrucciones De Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Speedaire Operating Instructions
Speedaire
Maintenance (Continued)
E

OIL CHANGE

N
1. Allow compressor to run and warm
G
up oil. Unplug unit.
L
2. Position a pan under pump end of
I
unit.
S
3. Remove drain plug. Allow oil to
H
collect in pan. Tilt unit to completely
drain.
4. Replace drain plug, fill pump to
full line on dipstick. Use Chevron
synthetic 5W-30, Mobil 1 5W-30 or
10W-30 synthetic motor oil. Using
other types of oil will cause starting
problems.
5. Change oil after every 50 hours of
use.
Air Compressors
®

AIR FILTER MAINTENANCE

1. Locate and remove the four Phillips
head screws on the air deflector over
the cylinder head of the pump.
2. Lift off cover to expose the air filter.
3. Remove filter. Clean with air blast
or soap and water. Replace filter if
clogged or damaged.
4. Replace air deflector and screws. Do
not operate without air deflector
as the pump will overheat and
become damaged.
IMPORTANT: Locate unit as far from
spraying area as hose will allow to
prevent overspray from clogging filter.
Deflector
Filter
Figure 6
6
THERMAL OVERLOAD PROTECTOR
This compressor is
equipped with
an automatic reset thermal overload
protector which will shut off motor if it
becomes overheated.
If thermal overload protector shuts
motor OFF frequently, look for the
following causes.
1. Low voltage.
2. Clogged air filter.
3. Lack of proper ventilation.
If the thermal
overload protector
is actuated, the motor must be allowed
to cool down before start-up is
possible. The motor will automatically
restart without warning if left plugged
into electrical outlet and unit is turned
on.
END OF OPERATION / STORAGE
1. Turn AUTO/off switch to the OFF
position.
2. Unplug power cord from wall outlet
and wrap around handle to prevent
damage when not in use.
3. Wearing safety glasses drain tank of
air by pulling the ring on the safety
valve. Use other hand to deflect
fast moving air from being directed
toward your face.
4. Drain tank of condensation by
opening drain valve on bottom of
tank. Tank pressure should be below
10 psi when draining tank.
5. Air hose should be disconnected from
compressor and hung open ends
down to allow any moisture to drain.
6. Compressor and hose should be
stored in a cool, dry place.