Electrical And Structural Requirements; Lighting Options - Fanimation FP1280 Serie Manual De Instrucciones

Ocultar thumbs Ver también para FP1280 Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
INSTALLATION NOTE
It is recommended that each fan and the motor have ¾
plywood backing secured to a structural member for
adequate support (Figure ). A 120 VAC electrical feed,
centered under the motor unit and wired to a 3 speed
control (supplied) is required. The motor unit will not
operate more than 2 pulley/blade assemblies.
If your fan is to replace an existing light
electricity off at the main fuse box at this time and remove
the existing light xture.
WARNING
Turning off wall switch is not sufficent.
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with National and Local codes and the
ceiling fan must be properly grounded as a precaution
against possible electrical shock.
instructions carefully. Any electrical work not described
in these instructions should be done or approved by a
licensed electrician.
Optional lighting tters and light kits are available, including a single bowl xture with a maximum of 180 watts and a
variety of four light xtures with a maximum of 240 watts. Can be only mounted on the motor switch cup. Installation
instructions provided with each light tter and light kit.

Electrical and Structural Requirements

xture, turn
To avoid
Follow all wiring

Lighting Options

2" Lag Bolt
& Flat Washer
6
Plywood (¾ thick min.)
Backing Secured to
Structural Member
Outlet Box Flush
to Finished
Ceiling
2" Lag
Bolt
& Flat
Washer
(4 places)
(4 places)
Figure 3

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido