Burner and nozzle specifications
GB
Table 1
I. Double flame DC DR (internal)
I. Double Flame DC DR (external)
Supply pressure
*
At 15°C and 1013 mbar - dry gas
**
Propane
***
Butane
Natural
! The hob can only be installed above built-in ovens with a cooling ventilation system.
BQ 40TC
BQ 40TC
BQ 40TC
BQ 40TC
BQ 40TC
PPF Q40TC BNV
PPF Q40TC BNV
PPF Q40TC BNV
PPF Q40TC BNV
PPF Q40TC BNV
B B B B B
D D D D D
C C C C C
BQ 40TC/CS
BQ 40TC/CS
BQ 40TC/CS
BQ 40TC/CS
BQ 40TC/CS
PPF Q40TC/CS
PPF Q40TC/CS
PPF Q40TC/CS
PPF Q40TC/CS
PPF Q40TC/CS
PP Q40 TC SF
PP Q40 TC SF
PP Q40 TC SF
PP Q40 TC SF
PP Q40 TC SF
B B B B B
D D D D D
C C C C C
20
Diameter
(mm)
130
100
75
55
30
130
P.C.S. = 50.37 MJ/Kg
P.C.S. = 49.47 MJ/Kg
P.C.S. = 37.78 MJ/m3
BQ 40DCDR
BQ 40DCDR
BQ 40DCDR
BQ 40DCDR
BQ 40DCDR
B B B B B
B B B B B
A A A A A
C C C C C
B B B B B
A A A A A
Thermal power
By-pass
kW (H.s.*)
1/100
Nomin. Reduc.
(mm)
3.25
1.3
57
3.00
0.7
40
1.65
0.4
30
1.00
0.4
30
0.90
0.4
30
4.10
1.3
57
Nominal
Minimum
B B B B B
I I I I I
A A A A A
BQ 40DCDR/CS
BQ 40DCDR/CS
BQ 40DCDR/CS
BQ 40DCDR/CS
BQ 40DCDR/CS
PPF Q40DCDR
PPF Q40DCDR
PPF Q40DCDR
PPF Q40DCDR
PPF Q40DCDR
B B B B B
C C C C C
Liquid gas
Injector
Flow *
1/100
g/h
(mm)
G30
91
236
232
86
218
214
64
120
118
50
73
71
44
65
64
70
298
293
28-30
37
20
25
35
45
BQ 50TC
BQ 50TC
BQ 50TC
BQ 50TC
BQ 50TC
A A A A A
C C C C C
D D D D D
B B B B B
B B B B B
I I I I I
A A A A A
Natural gas
Injector
Flow*
1/100
l/h
(mm)
124
309
116
286
96
157
71
95
70
86
110
390
20
17
25
B B B B B
A A A A A