ELECTRICAL CONNECTIONS
Receiver
Mounting Bracket
WARNING: To avoid possible electrical shock, be sure you have turned off the power
at the main circuit panel before wiring.
Follow the steps below to connect the fan to your household wiring. Use the wire
connectors supplied with your fan. Secure the connector with electrical tape. Make
sure there are no loose wire stands or connections.
WARNING: If your house wires are different colors than referenced in this manual,
Fig. 13
stop immediately. A professional electrician is recommended to determine proper
wiring.
Outlet Box
Step 1. Insert the receiver into the mounting bracket, and keep flat in opposition of
White
ceiling. (Fig. 13)
Black
Green or bare copper
(ground)
Step 2. Motor to Receiver Electrical Connections:
White ("AC IN N")
Black ("AC IN L")
Connect the BLACK wire from the fan to BLACK wire marked "TO MOTOR L" from
the receiver. Connect the WHITE wire from the fan to the WHITE wire marked "TO
Receiver
MOTOR N" from the receiver. Connect the BLUE wire from the fan to the BLUE wire
Black ("TO MOTOR L")
White ("TO MOTOR N")
marked "FOR LIGHT " from the receiver. Secure all the wire connections with the
plastic wire connectors provided. (Fig. 14)
Black (motor)
Ground wire
Blue (FOR LIGHT)
Step 3. Remote Receiver to Outlet Box Electrical Connections:
White (Neutral)
Blue (for light)
Connect the BLACK (hot) wire from the ceiling to the BLACK wire marked "AC IN L"
from the receiver. Connect the WHITE (Neutral) wire from the ceiling to the WHITE
wire marked " AC IN N" from the receiver. Secure all the wire connections with the
plastic wire connectors provided. (Fig. 14)
Fig. 14
10 | KICHLER.COM