Important Notice - Zoeller 292-0002 Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

L1
L2
WHITE
GREEN
BLACK
BLACK
WHITE
RUN
CAPACITOR
FLOAT
SWITCH
BLUE
RED
(1)
(2)
BLUE
RED
(WHITE)
(BROWN)
MOTOR
START
RUN
011835
WIRING DIAGRAM FOR MODELS
D 230 , 1 h, 60 z.
200/208 , 1 h, 60 z.
FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING. Single phase pumps
are supplied with a 3 prong grounded plug to help protect you against the possibility of electrical shoc . DO NOT UNDER ANY CIRCUMSTANCES
REMOVE THE GROUND PIN. he 3 prong plug must be inserted into a mating 3 prong grounded receptacle. If the installation does not have such
a receptacle, it must be changed to the proper type, wired and grounded in accordance with the National lectrical Code and all applicable local codes
and ordinances.
Risk of electrical shock. Do not remove power supply cord and strain relief or connect conduit directly to the pump.
Installation and chec ing of electrical circuits and hardware should be performed by a uali ed licensed electrician.
nits supplied without a plug single and three phase and single phase nonautomatic units with a 20 amp plug must have a motor control
and li uid level control provided at time of installation. he control device should have suitable voltage, ampere, fre uency, grounding and horsepower
rating for the pump to which it is connected.
FOR YOUR PROTECTION, ALWAYS
DISCONNECT PUMP FROM ITS POWER SOURCE
BEFORE HANDLING.
o automatically operate a nonautomatic three phase pump, a
control panel is re uired. Follow the instructions provided with
the panel to wire the system. For automatic three phase pumps,
see automatic 3 phase wiring diagram located to the far right.
efore installing a pump, chec the pump rotation to ensure that
wiring has been connected properly to power source, and that
the green lead of power cord see wiring diagram is connected
to a valid ground. Momentarily energize the pump, observing the
directions of ic bac due to starting tor ue. Rotation is correct if
ic bac is in the opposite direction of rotation arrow on the pump
casing. If rotation is not correct, switching of any two power leads
other than ground, should provide the proper rotation.
ll three phase pumps re uire motor starting devices with motor
overload protection. See FM0486 for duple installations. umps
must be installed in accordance with the National lectrical Code
and all applicable local codes and ordinances. umps are not to
be installed in locations classi ed as hazardous in accordance
with National lectrical Code, NSI/NF
IMPORTANT NOTICE: Some insurance policies, both commercial and residential, e tend coverage for damages incurred by product failure. ou will need to
have possession of the product to support your claim in most cases. Zoeller ump Co. will e change the unit or refund the original purchase price once the claim
is settled with the insurer in the case where you need to retain possession of the product to support a damage claim you submit to your insurance company.
WD & WH MODEL INSTALLATION
ether ength
umping ange 9 13.5 18 22 24
se only as a guide. Due to weight of
cable, pumping range above horizontal
is not e ual to pumping range below
horizontal. Ranges are based on testing in
nonturbulent conditions. Range may vary
(3)
due to water temperature and cord shape.
YELLOW
(BLACK)
s tether length increases, so does the
variance of the pumping range.
O.L.
Models D &
factory wired in the pump circuit to provide automatic operation
once the oat switch is secured properly to the outlet pipe. se
the diagram above to secure the oat switch properly and obtain
the proper tether to customize the on off cycle to each application.
SINGLE PHASE WIRING INSTRUCTIONS
THREE PHASE WIRING INSTRUCTIONS
70.
© Copyright 2015 Zoeller
Determining Pumping Range
in Inches (1 inch = 2.5 cm)
5 10 15 20 22
are fully automatic.
oat switch is included and
NONAUTOMATIC
3 PHASE
L1
L2
L3
GREY
BROWN
GREEN/YELLOW
BLACK
(1)
BLUE
MOTOR
®
Co. All rights reserved.
4
20 AMP SWITCH (WD & WH MODELS)
Note: Failure to eep within proper tether limits
may prevent reliable switch operation.
Note: Cable must be mounted in horizontal
position.
L1
L2
L3
WHITE
RED
BLACK
GREEN
BLUE
(2)
(3)
BLUE
RED
YELLOW
006848
5" MIN.
(127 mm)
22" MAX.
(559 mm)
AUTOMATIC
3 PHASE
WHITE
RELAY
7
4
COM
1
3
A
RED
NC
4
2
8
5
CR
FLOAT
B
9
6
WHITE
WHITE
RED
YELLOW
(1)
(2)
(3)
(M1)
(M2)
TAN
ORANGE
PURPLE
PURPLE
OR BROWN
THERMOSTAT
WINDINGS
Tabla de contenido
loading

Tabla de contenido