5.6 Segments test
Segments test is activated by pressing simul-
taneously the reset key and the keys of the
5th and 6th decades. Init 5 is then displayed;
release immediately the keys, the segment test
is started and all display segments are displa-
yed. Pressing the 1st decade key calls up the
programming mode; all parameters must then
be re-programmed.
6. Terminal assignment
Terminal
no.
1
+3 VDC for key lock on terminal 2
2
Key lock input
3
Relay contact
4
Relay contact
AC/DC optocoupler counting input /
5
start input (.820) / NPN counting input
/ start input (.850)
AC/DC optocoupler reset input (.820)
6
/ NPN reset input (.850)
Common AC/DC input (.820) / 0V
7
input (.850) for terminals 6 and 5
Page 6 | ENG
7. Connection example
Device type:
x.901.xxx.820
12 ... 250 VAC/VDC
Key lock
V AC/DC
Reset
Device type:
x.901.xxx.850
NPN
Key lock
Count/
Reset
Start
8. Factory programming:
Function(Funct):
Counting mode(Count):
Auto. repetition(LooP):
Output contact(rELAY):
Output signal duration(dELAY):
Decimal point(dP):
Count/
Start
counter(Count)
adding(add)
none(oFF)
normally open
bistable output(0.0)
none(0)