❼ Troubleshooting; I User Alerts - Zodiac eXPERT Manual De Instalación Y De Uso

Ocultar thumbs Ver también para eXPERT:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 167
❼ Troubleshooting
7
• Before you contact the retailer, carry out these few simple checks using the following table if
a problem occurs.
• If the problem is not resolved, contact your retailer.
: Actions to be performed by a qualified technician only
7.1 I User alerts
Message
• The appliance automatically exits Calibration
mode after two minutes without any action
by the user. This message then appears
briefly on the screen.
• The value detected during calibration differs
greatly from the expected value, making
calibration impossible.
• The value detected during calibration is
unstable, making calibration impossible.
• The pH pump fuse is faulty.
• The pH pump has stopped.
• Steady red: The temperature setpoint is
lower or higher than the measured value
(not blocking)
• Flashing: Water conductivity problem: the
appliance is not reaching 100% production
• Steady red: The salt concentration setpoint
is lower or higher than the measured value
(not blocking)
• Flashing: Water conductivity problem: the
appliance is not reaching 100% production
• Steady red: The pH setpoint is lower or higher
than the measured value (not blocking)
• Steady red: The ORP setpoint is lower
or higher than the measured value (not
blocking)
• Short-circuit in the cell or cell not properly
connected.
• Worn electrode: the cell is worn out
Possible cause
Solution
• Information only, no issue.
• If needed, restart the calibration process from the
beginning, see § "4.4 I Calibrating the sensors (pH or
pH/ORP models)".
• Visually check the condition of the sensor and rinse
it.
• Repeat the measurement in a buffer solution, wait
15 seconds, then recalibrate if the measurement is
incorrect.
• Clean the sensor or replace if necessary.
• Check the pH pump to ensure it's not damaged.
• Replace the pH pump fuse (inside the chlorinator
power pack).
• pH setpoint has not been reached within allocated
time frame.
• Check pH value and calibrate the pH sensor if
needed.
• Check pH pump tubing and container to ensure pH
minus can be injected.
• Adjust the alarm trigger time, see § "4.3.10. "Pump
stop": pH pump stop over feed alarm (pH - PH/ORP
models)".
• Reset the alarm: press
• Check the alarm triggering range (see § "4.3 I
Settings that can be accessed in Configuration
mode").
• Check the electrode wiring: ensure compliance with
the numerical codes and the colours (see § "2.1.3.
Connecting the cell to the control box")
• Check the water temperature.
• Check the condition of the cell plates.
• Measure the salt concentration in the pool water
using a salt tester or a test strip, then add salt to
the pool to keep the level at 4 or 5 g/L. Consult your
retailer if necessary.
• Check the cell connections.
• Replace the cell if necessary: consult your retailer
EN
40
Tabla de contenido
loading

Tabla de contenido