I Installing The Ph Pump; (Ph & Ph/Orp, Depending On Model) - Zodiac eXPERT Manual De Instalación Y De Uso

Ocultar thumbs Ver también para eXPERT:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 167
2.4 I Installing the pH pump
• When handling chemical products, always use appropriate safety equipment (safety
glasses, gloves, jacket and mask).
• The pH pump is a peristaltic pump that rotates in the clockwise direction: it sucks up acid (pH-minus) to inject into
the pool.
2.4.1. Installing the pH minus injection line
• Cut a suitable length of white hose from the coil (supplied) to connect the ppH pump to the injection check valve.
• Unscrew the connector cap and attach the hose to the connector at the outlet of the pH pump, see figure
Screw the cap in place.
• Attach the other end of the hose to the injection check valve, see figure
13
(pH & pH/ORP, depending on model)
: Support tip
: Ceramic weight
: pH-minus container
: Suction hose
: pH pump
: Inlet
: Outlet
: Injection hose
: Injection check valve
.
.