Battery Pump CT-2902BPHP
5.
Troubleshooting
a.) Constant fl ashing/indicating of the red LED (pic 1.10) or the occurence of an acoustical warning signal.
see tab. 2. If the failure can not be resolved through the action recommended in tab. 2 return the unit to the
nearest service center (ASC).
b.) The tool or the crimping-/cutting- or punching-head loses oil.
Return the unit or the accessories to the manufacturer. Do not open it and damage the seal of the tool.
c.) The red LED fl ashes 3x and simultaneously 3 acoustic warning signals occur.
Serious fault! If this fault occures repeatedly return the unit to an Autorized Service Center (ASC). Do not open
it and damage the seal of the tool.
In case of a one time occurence, the connector has to be pressed a second time.
6.
Technical Data
max. operation pressure:
Hydraulic oil:
Reservoir capacity:
Useable oil capacity:
Environmental temperature:
Control voltage:
Driving motor:
Weight of the unit:
Battery voltage:
Battery capacity:
Charging time:
Sound level:
Vibrations:
HE17600_C © 09/2016
700 bar
Rivolta S.B.H. 11
approx. 760 ml
approx. 740 ml
-12°C to +40°C
18 V DC
direct-current permanent fi eld
approx. 4,9 kg
18 V
4 Ah (RAL40/BL1840)
36 min. (RAL40/BL1840)
< 70 dB (A) in 1m distance
< 2,5 m/s²
Intended Use
I.XI