Attention
After having terminated the working cycle and prior to changing the dies remove battery to avoid un-
intended use. Avoid unintended starts. Make sure the switch is in the off position before plugging in.
For transport turn the program selection switch to position 7 to avoid unintended starts.
4.2 Explanation of the application range
The battery hydraulic pump can be operated with all of the cutting-/crimping- and punching heads in our catalogue.
Attention
Do not crimp/cut or punch on live cables or conductors.
Before starting to work make sure there are no live lines in the working area.
The tool is not designed for continued operations. After a sequence of approximately 100 completed cycles you have
to make a break of 15 min. to give the tool time to cool down.
Attention
Too intensive use can cause heat damages for the tool
Attention
During the operation of electric engines sparks can occur which might ignite highly infl ammable or
explosive liquids and materials
Attention
Electric-hydraulic tools should not be operated in pouring rain or under water.
The tool can be operated in a temperature range of -12°C to +40°C inside as well as outside.