FIGURE 9A
EZLogic Controller
(Controlador EZLogic)
4-way Solenoid Valve
3-way Solenoid Valve
(Válvula de solenoide de 4 vías)
(Válvula de solenoide de 3 vías)
FIGURE 9B
TO BRAKE AIR BAG
(HACIA LA BOLSA DE AIRE
M8 CONNECTOR (TO
EZLOGIC SOLENOID CABLE)
(CONECTOR M8 [AL CABLE DE
SOLENOIDE DE EZLOGIC])
(SILENCIADOR)
• EZLOGIC® ZONE CONTROLLER
DEFAULT SETTINGS
The zone controllers will be set for the default settings when the unit leaves
the factory. However, if you need to replace a zone controller, the new zone
controller will need to have parameters changed so that the zone will operate
properly.
To make the changes, you will need the EZLogic® OS configuration
software installed on a PC and a USB programming cable. Connect the USB
programming cable to a USB port on the PC and the other end to the auxiliary
port on the zone controller. Make sure the zone controller is powered by the
IOP or from another 24-27VDC power source. Start EZLogic® OS by double-
clicking its icon on your desktop. When the software opens, navigate to the
File menu. From the Load from Defaults submenu, select the E24EZ as the
default configuration, click SAVE, click OK. Next, select the Configuration from
the main menu options. Make the following changes to the parameters:
•
Singulate/Slug – change to Slug Only – Click SAVE
•
Special Logic Function – select High-Speed Accumulation
o
Click NEXT (Select the default timer setting. This can be changed later if
necessary.)
o
Click SAVE
Your new zone controller is now programmed for default NBEZ/NBEZA
settings. The EZLogic® OS configuration screen should look like this:
TO DRIVE AIR BAG
(HACIA LA BOLSA
DEL FRENO)
DE AIRE DEL
ACCIONAMIENTO)
MUFFLER
MUFFLER
(SILENCIADOR)
AIR IN
(ENTRADA DE AIRE)
FIGURE 9D
9
FIGURE 9C
M8 CONNECTOR (TO
EZLOGIC SOLENOID CABLE)
(CONECTOR M8 [AL CABLE DE
SOLENOIDE DE EZLOGIC])
AIR IN
(ENTRADA DE AIRE)
TO DRIVE AIR BAG
(HACIA LA BOLSA DE
AIRE DEL FRENO)