PROBLEM
Engine shuts down
during operation.
Engine lacks power.
Engine surges or
stumbles.
Engine starts and shuts
off right away.
Owner's Manual for Portable Generator
CAUSE
1. Out of fuel.
2. Low oil level.
3. Fault in engine.
4. CO-SENSE shut-off due to
accumulating carbon monox-
ide if a red light blinks on the
side panel badge.
5. CO-SENSE shut-off due to a
system fault if a yellow light
blinks on the side panel
badge.
1. Load is too high.
2. Dirty air filter.
3. Engine needs to be serviced.
4. Clogged spark arrestor.
1. Carburetor is running too rich
or too lean.
1. CO-SENSE shut-off due to
accumulating carbon monox-
ide if a red light blinks on the
side panel badge.
2. CO-SENSE shut-off due to a
system fault if a yellow light
blinks on the side panel
badge.
CORRECTION
1. Fill fuel tank.
2. Fill crankcase to correct level.
3. Contact IASD.
4. Follow all safety instructions
and relocate generator to an
open area outside, far away
from windows, doors and
vents.
5. Start to confirm yellow light
blinks when/if generator shuts-
off. If CO-SENSE continues to
fault and shut-off, contact
IASD.
1. Reduce load (see
erator Limits
).
2. Clean or replace air filter.
3. Contact IASD.
4. Clean spark arrestor screen.
1. Contact IASD.
1. Follow all safety instructions
and relocate generator to an
open area outside, far away
from windows, doors and
vents.
2. Start to confirm yellow light
blinks when/if generator shuts-
off. If CO-SENSE continues to
fault and shut-off, contact
IASD.
Know Gen-
17