Approved Accessories Within The Ex-Area; Ex-Data - Ecom Ex-PMR 2000 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 71
- The cover of the headset socket must be kept closed when the headset is
not connected.
- Only Ex-AM PMR 2000 batteries specified by the manufacturer may be used.
- The use of other batteries is strictly prohibited and will result in the nullification
of Ex-protection.
- The battery should only be charged outside the Ex-area using the appropri-
ate charger LS PMR 2000 and the corresponding power supply unit PS
PMR 2000, the multi-charger MC PMR 2000 or the car charger WTC638.
- The screws must be re-tightened after changing the battery.
- Only the corresponding Ex-HS 02 or Ex-EPM 02 microphone / loudspea-
ker combination may be connected to the headset connection within the
hazardous area. The headset must be connected outside the hazardous
area.
- Only the corresponding EP 1 earphone may be connected to the Ex-HS
02 microphone / loudspeaker combination within the hazardous area.
The headset must be connected outside the hazardous area.
- The unit must only be cleaned using a damp cloth.
- Only approved accessories from ecom instruments GmbH may be used.
- It must be ensured that the unit is not taken into zone 0.

5. Approved accessories within the Ex-area

Battery:
• Battery pack Ex-AM PMR 2000
Headset connection:
• Microphone/loudspeaker combination Ex-HS 02
or
• Ex-EPM 02
Ex-HS 02 earphone connection:
• Earphones EP 1

6. Ex-Data

EC-Type Examination Certificate No.:
Ex-Designation:
Approved for:
Zone 1 and 2, device group II, explosion group IIC explosive gases, vapours
or mist, temperature class T4
22
ZELM 06 ATEX 0318
II 2 G Ex ia IIC T4
Tabla de contenido
loading

Tabla de contenido